Roberts Gorden TF-Series ± 2 5 cm, on Page 28, Section , when using, dimensions, position

Models: TF-Series

1 44
Download 44 pages 59.4 Kb
Page 18
Image 18
Tighten slide bar as shown below

ROBERTS GORDON ® TF-SE RIE S SU BMI TT AL SHEE T

Coupling and Tube Assembly (Continued)

Tighten slide bar as shown below

Drive Slide Bar until tight. End of Slide Bar should be within tolerance listed below.

 

± 2" (5 cm)

 

 

Correct Slide Bar

 

 

 

dimensions

Incorrect Slide Bar

 

 

 

position

 

 

• Repeat

A - D until all tubes are assembled.

 

 

Coupling and Tube Assembly (Continued)

 

 

 

 

Tube Length Per Side

 

Model

Minimum

Maximum

 

TF-120

20’ (6 m)

20’ (6 m)

 

TF-160

20’ (6 m)

30’ (9 m)

 

TF-200

30’ (9 m)

40’ (12 m)

 

TF-250

40’ (12 m)

50’ (15 m)

 

TF-300

50’ (15 m)

60’ (18 m)

 

TF-350

50’ (15 m)

70’ (21 m)

 

TF-380

60’ (18 m)

80’ (24 m)

See recommended venting lengths

on Page 28, Section , when using

maximum tube lengths.

7' 6" ± 1'

(229 cm ± 25 cm)

10' Typ. ± 1'

(254 cm Typ ± 25 cm)

© 2004 Roberts-GordonAPPLI CATIONS, ENGIN EERING AND DETAI LED GUIDANCE ON SYSTEMS DESI GN, I NSTALLATION AND PRODUCT PERFORMANCE I S AVAILABLE UPO N REQUEST. ROBERTS GO RDON® PRODUCTS ARE TO BE INSTALLED ONLY I N ACCOR DANCE WITH LOCAL LAW S, CODES AND REGULATIONS, AND ONLY BY A CONTRACTO R QUALI FIED IN THE INSTALLATION AND SERVICE OF GAS-F IRED HEATING EQUIPMEN T.