Roberts Gorden TF-Series service manual TF-120, TF-160, TF-200, TF-250, TF-300, TF-350

Models: TF-Series

1 44
Download 44 pages 59.4 Kb
Page 22
Image 22
Manual background

ROBERTS GORDON ® TF-SE RIE S SU BMI TT AL SHEE T

TF-Series U-Tube Layout Overviews

U-tube layouts showing one side. Use same measurements for the other side.

 

 

 

 

 

 

 

 

bc

 

 

 

 

LEGEND

 

 

 

 

 

 

 

Burner

 

g

 

 

e

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reflector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tube 10' (3m)

h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tube 5' (1.5m)**

 

TF-120

20' (6m) Tube Length* (each side)

 

 

 

 

 

 

 

 

 

 

 

 

TF-160

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tube/Reflector

 

bc

 

 

Hanger

 

 

 

Coupling

g

d

f

 

Assembly

 

 

 

 

U-Tube

 

 

 

a =

14" (36 cm)

h

 

 

reflector width (not shown)

 

 

b =

2" (5 cm)

TF-160

30' (9m) Tube Length**(each side)

end cap to burner

TF-200

 

 

c = 2" (5 cm)

bc

end cap to hanger

d = 7'6" (229 cm)

g

d

e

 

distance first hanger

 

 

 

 

e = 10' (305 cm)

 

 

 

 

distance between hangers

 

 

 

 

f = 5' (153 cm)

h

 

 

 

distance between last full tube

 

 

 

 

hanger and half tube hanger

TF-200

40' (12m) Tube Length (each side)

 

g = 17.5" (44 cm)

TF-250

 

 

 

 

 

 

 

burner length

 

 

 

 

h = 9.5" (24 cm)

 

bc

 

 

burner height

g

d

e

f

 

*Requires the last reflector

 

 

 

 

before the U-Tube to be cut

 

 

 

 

in half for use on both sides.

 

 

 

 

**Requires the last tube before

h

 

 

 

 

 

 

 

 

 

 

the U-Tube to be cut in half for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

use on both sides.

 

 

 

 

 

 

 

TF-25050' (15m) Tube Length* ** (each side)

 

 

 

 

TF-300

 

 

TF-350

© 2004 Roberts-GordonAPPLI CATIONS, ENGIN EERING AND DETAI LED GUIDANCE ON SYSTEMS DESI GN, I NSTALLATION AND PRODUCT PERFORMANCE I S AVAILABLE UPO N REQUEST. ROBERTS GO RDON® PRODUCTS ARE TO BE INSTALLED ONLY I N ACCOR DANCE WITH LOCAL LAW S, CODES AND REGULATIONS, AND ONLY BY A CONTRACTO R QUALI FIED IN THE INSTALLATION AND SERVICE OF GAS-F IRED HEATING EQUIPMEN T.

Page 22
Image 22
Roberts Gorden TF-Series service manual TF-120, TF-160, TF-200, TF-250, TF-300, TF-350