5

Making fine adjustments to the location at which a sample starts/ends

Using scrub to set a point—Scrub Preview
Scrub Preview repeatedly plays an extremely brief region (45 milliseconds) either
before or after the point. At the same time, the sample waveform will be displayed
in the screen. While monitoring the displayed waveform and the sound, you can
turn the TIME/VALUE dial to easily make precise adjustments to the point.
1. Press PAD RECORDING [TEMPO MATCH] twice.
Alternatively, press [TEMPO MATCH] and then press CURSOR [ ].
fig.31-03
The Pad Edit menu are displayed as icons.
fig.33-07
2. Press CURSOR [ ] [ ] to select the
Pad Parameter icon.
3. Press [YES/ENTER].
The Pad Parameter screen appears.
fig.33-08
4. Press CURSOR [ ] [ ] to move the
cursor to the point “Start Point,” “Loop
Point,” or “Length(End)” you want to
adjust.
5. Press [SCRUB].
fig.33-08
[SCRUB] lights, the Wave View screen
appears.
The sound either before or after the point will
play repeatedly.
6. While monitoring the sound and the screen, turn the TIME/VALUE dial to make
fine adjustments to the point.
As necessary, you can switch the region that is repeated, or switch the screen display.
[TO]: Repeatedly play from a point 45 milliseconds before the current point,
up to the current point.
[FROM]: Playback once from the current point to one second after the current
point.
CURSOR [ ]: Expand the waveform vertically (amplitude axis).
CURSOR [ ]: Shrink the waveform vertically (amplitude axis).
CURSOR [ ]: Expand the waveform horizontally (time axis).
CURSOR [ ]: Shrink the waveform horizontally (time axis).
7. Press [SCRUB].
[SCRUB] go out, the Pad Parameter screen reappears.
8. Press [DISPLAY] to return to the Basic screen.
45 msec