195

Settings Common to All Modes (System Function)

Settings Common to All Modes (System Function)

Sampling

Default File Type

Specifies the file format used when saving a sample.

Value:

WAV, AIFF

Pre Sample Time

0–1000 ms

Value:

OFF, ON
The length of sound preceding the moment at which sampling was
manually or automatically initiated that will be captured in the
sample. This lets you prevent the attack portion of the sound from
being omitted from the sample.

Trigger Level

Volume level at which sampling will begin when Auto Trig is ON
A setting of 0 is the minimum.

Value:

0–7

Gap Time

Length of silence at which the sample will be divided
Whenever there is a silent region longer than the specified time, the
sample will be divided at that point, and the next sample number
will be assigned to the sound that follows. This parameter is valid
only when you are using Auto Divide Sampling.

Value:

500, 1000, 1500, 2000 ms

External Source Select

Input source of the external input sound

Value
LINE-L-R:

INPUT jacks L/R (stereo)

LINE-L:

INPUT jack L (mono)

MIC:

INPUT jack (mono, mic level)

Trimming Switch

If this is turned on, the Start point and End point settings will be
automatically adjusted after sampling is performed, so any silent
portions at the beginning or end of the sampled sound are excluded.

Value:

OFF, ON

Skip Back Time

Specifies how much earlier in time that you want sampling to take
place when you use Skip Back Sampling. If “OFF” selected, skip-
back sampling cannot be performed.

Value:

OFF, 5s–40s

Start up

Preset Default Load

Specifies whether the preset samples will be loaded into memory at
power-on (ON) or not (OFF).

Value:

OFF, ON

Sample Default Load

Specifies whether the samples of the user area and memory card will
be loaded into memory at power-on (ON) or not (OFF).

Value:

OFF, ON

Power Up Mode

This setting allows you to choose the mode that you want the
Fantom-S to be in when it is powered up.

Value
PATCH:

The Fantom-S will be in Patch mode when you
turn on the power.

PERFORMANCE:

The Fantom-S will be in Performance mode when
you turn on the power.

SRX/RAM Mode

The Fantom-S provides four slots (A–D) for SRX series expansion
boards. This setting specifies whether all of these slots will be
available (x4) or only slots A and B will be available (x2). If you have
installed a 256 MB DIMM module, setting this to “2 SRX/288MB
Max” will change the amount of memory that will be available as
sample memory.

* If a 512 MB DIMM is installed, the result will be the same as if a 256
MB DIMM were installed.

Range
2 SRX/288MB Max:

Only EXP slots A and B will be available.

4 SRX/192MB Max:

EXP slots A–D will all be available.

* The settings of this switch takes effect when the power is turned on.

System Information

For details on the indicating, refer to

“How to Make the System
Function Settings”

(p. 188).

Features

Displays the main features of the Fantom-S.

Memory Info (Memory Information)

Displays the amount of memory installed.

SRX Info (SRX Information)

Displays the name of the wave expansion board that is installed.

Version Info (Version Information)

Displays the version of the Fantom-S.

Installed DIMM Amount of available
sample memory

512 MB 288 MB
256 MB 288 MB
128 MB 160 MB
64 MB 96 MB
0 MB 32 MB

Installed DIMM Amount of available
sample memory

512 MB 192 MB
256 MB 192 MB
128 MB 160 MB
64 MB 96 MB
0 MB 32 MB
Reference_e.book 195 ページ 2003年7月14日 月曜日 午後3時25分