80
Switching the Sampling Rate
Use the front panel [SAMPLE RATE] knob to select the sampling rate. To make the system reflect the new setting,
you’ll need to cycle the power to the system. If you need to synchronize the VS-700 to another digital device, you
must first set this knob to the same sampling rate as the master device.
1.
Close the software you’re using.
2.
Switch off the power to the VS-700R I/O and the VS-700C console.
3.
Set the VS-700R I/O’s [SAMPLE RATE] knob to the desired sampling rate.
4.
Power up the VS-700C console.
5.
Power up the VS-700R I/O.
6.
Wait for the USB indicator to light.
7.
Switch the sampling rate in your software.
“Setting SONAR’s Sampling Rate”
(p. 81)
The number of channels that can be used will depend on the sampling rate.
44.1/48 kHz 88.2/96 kHz 192 kHz
Input 1–8 884
Digital 1 In 2 2 0
Digital 2 In 8 4 0
AUX 1 1 1
Total input channels 19 15 5
Main Out 2 2 2
Sub Out 2 2 2
Output 1–10 10 10 6
Digital 1 Out 2 2 0
Digital 2 Out 8 4 0
Total output channels 24 20 10
VS-700_r_e.book 80ページ 2008年11月20日 木曜日 午後2時28分