Rotel RC-1082 Troubleshooting, Specifications, English, Standby Power Indicator Is, Not Lit

Models: RC-1082

1 56
Download 56 pages 41.21 Kb
Page 9
Image 9
English

 

 

9

English

 

 

 

 

NOTE: By default, the RR-AT97 operates

 

 

the Rotel RT-1080/RT-961/RT-955 tuners.

 

 

The remote can be reprogrammed to oper-

 

 

ate the RT-940AX tuner. This programming

 

 

only needs to be done once:

 

 

To program for the RT-940AX: press

 

 

the ON button and the 2 button simultane-

 

 

ously.

 

 

To program for the RT-1080/

 

 

RT-961/RT-955:press the ON button

 

 

and the 1 button simultaneously.

 

 

 

 

 

 

Troubleshooting

 

 

Most difficulties in audio systems are the result

 

 

of incorrect connections, or improper control

 

 

settings. If you encounter problems, isolate the

 

 

area of the difficulty, check the control settings,

 

 

determine the cause of the fault and make the

 

 

necessary changes. If you are unable to get

 

 

sound from the RC-1082, refer to the sugges-

 

 

tions for the following conditions:

 

 

Standby Power Indicator Is

 

 

Not Lit

 

 

The Standby Power Indicator should be lit

 

 

whenever the RC-1082 is plugged into the

 

 

wall power outlet. If it does not light, test the

 

 

power outlet with another electrical device,

 

 

such as a lamp. Be sure the power outlet be-

 

 

ing used is not controlled by a switch that has

 

 

been turned off.

Specifications

 

Fuse Replacement

 

If another electrical device works when plugged

 

 

into the power outlet, and the Standby Indicator

Total Harmonic Distortion (20Hz-20kHz)

< 0.004%

still will not light when the RC-1082 is plugged

Intermodulation Distortion (60 Hz : 7 kHz, 4:1)

< 0.004% at 1V output

into the wall outlet, it indicates that the internal

Input Sensitivity / Impedance

 

power fuse may have blown. If you believe this

Phono - MC

250 µV / 100 ohms

has happened, contact your authorized Rotel

Phono - MM

2.5 mV / 47 kOhms

dealer to get the fuse replaced.

Line Level

150 mV / 220 kOhms

No Sound

Phono Overload (MC/MM)

16 mV / 160 mV

Output Sensitivity / Impedance

1 V/ 100 Ohms

Check the signal source to see if it is functioning

Frequency Response

 

properly. Make sure the cables from the signal

Phono Input

20Hz-20kHz, ± 0.2dB

source to the RC-1082 inputs are connected

Line Level Input

4Hz-100kHz, ± 0.5dB

properly. Be sure the Listening Selector is set

Signal to Noise Ratio (IHF “A” weighted)

 

to the proper input. Check the power ampli-

Phono - MC/MM

70 dB/75 dB

fier for power and proper operation. Check

Line Level

100 dB

all the wiring between the RC-1082 and the

Power Requirements

 

power amplifier, and the power amplifier

USA Version

120 Volts, 60 Hz

and speakers.

European Version

230 Volt, 50 Hz

 

 

Power Consumption

15 Watts

 

 

Standby Power Consumption

2.5 Watts

 

 

Dimensions (W x H x D)

432 x 92 x 344 mm

 

 

 

17 x 3 5/8 x 13 9/16

 

 

Weight (net)

7.5 kg, 16.53 lbs.

All specifications are accurate at the time of printing.

Rotel reserves the right to make improvements without notice.

Page 9
Image 9
Rotel RC-1082 Troubleshooting, Specifications, English, Standby Power Indicator Is, Not Lit, Fuse Replacement, No Sound