4.2 Power Supply Wiring and Grounding
Philips Screw Terminal with Cover | Philips Screw Terminal without Cover |
Safety Cover | Safety Cover | Chassis Ground | Surge / Chassis | Terminal |
| Screws | Connection | Ground Jumper |
|
Figure 6: RS416 Series Philips Screw Terminal Block
Phoenix Plug Terminal with Cover | Phoenix Plug Terminal without Cover |
Safety Cover | Safety Cover | Chassis Ground | Surge / Chassis | Terminal |
| Screws | Connection | Ground Jumper |
|
Figure 7: RS416 Series Phoenix Plug Terminal Block
The RS416 supports dual redundant power supplies – “Power Supply 1 (PS1)” and “Power Supply 2 (PS2)”. The connections for PS1, PS2 and the fail-safe relay are located on the terminal block as shown in Figure 6 and Figure 7.
The RS416 can be equipped with either a Philips Screw Terminal Block or a Phoenix Plug Terminal Block. The Philips Screw Terminal Block has Philips screws with a compression plate allowing either bare wire connections or crimped terminal lugs. We recommend the use of #6 size ring lugs to ensure secure, reliable connections under severe shock or vibration. Both terminal blocks have a safety cover which must be removed via two Phillips screws before connecting any wires. The safety cover must be
13
2008 RuggedCom Inc. All rights reserved | Rev104 |