RuggedCom RX1501 EMI And Environmental Type Tests, Test Description Test Levels Severity, Esd

Models: RX1501

1 46
Download 46 pages 25.61 Kb
Page 43
Image 43

5. EMI And Environmental Type Tests

5. EMI And Environmental Type Tests

Test

Description

Test Levels

Severity

Levels

 

 

 

 

IEC 61000-4-2

ESD

Enclosure Contact

+/- 8 kV

4

 

 

 

Enclosure Air

+/- 15 kV

4

 

 

 

 

 

 

 

IEC 61000-4-3

Radiated RFI

Enclosure Ports

20 V/m

Notea

 

 

Signal ports

+/- 4kV @ 2.5kHz

Notea

IEC 61000-4-4

Burst (Fast Transient)

D.C. Power ports

+/- 4kV

4

 

 

 

A.C. Power ports

+/- 4kV

4

 

 

 

 

 

 

 

 

 

Earth ground ports

+/- 4kV

4

 

 

 

 

 

 

 

Signal ports

+/- 4kV line-to-earth,

4

 

 

+/- 2kV line-to-line

 

 

 

 

 

 

 

 

 

IEC 61000-4-5

Surge

D.C. Power ports

+/- 2kV line-to-earth,

3

+/- 1kV line-to-line

 

 

 

 

 

 

 

 

 

 

 

A.C. Power ports

+/- 4kV line-to-earth,

4

 

 

+/- 2kV line-to-line

 

 

 

 

 

 

 

 

 

 

 

Signal ports

10V

3

 

 

 

 

 

IEC 61000-4-6

Induced (Conducted) RFI

D.C Power ports

10V

3

 

 

 

A.C. Power ports

10V

3

 

 

 

 

 

 

 

 

 

Earth ground ports

10V

3

 

 

 

 

 

 

 

 

40 A/m, continuous,

Notea

IEC 61000-4-8

Magnetic Field

Enclosure Ports

1000 A/m for 1 s

 

 

 

 

1000 A/m for 1 s

5

 

 

 

 

 

 

 

D.C. Power ports

30% for 0.1s, 60% for

N/A

 

 

0.1s, 100% for 0.05s

IEC 61000-4-29

Voltage Dips & Interrupts

 

 

 

 

 

A.C. Power ports

30% for 1 period,

N/A

 

 

 

 

60% for 50 periods

 

 

 

 

 

 

 

 

 

IEC 61000-4-11

Voltage Dips & Interrupts

A.C. Power ports

100% for 5 periods,

N/A

100% for 50 periods

 

 

 

 

 

 

 

 

 

 

 

Signal ports

2.5kV common, 1kV

3

 

 

diff. mode@1MHz

 

 

 

 

 

 

 

 

 

IEC 61000-4-12

Damped Oscillatory

D.C. Power ports

2.5kV common, 1kV

3

diff. mode@1MHz

 

 

 

 

 

 

 

 

 

 

 

A.C. Power ports

2.5kV common, 1kV

3

 

 

diff. mode@1MHz

 

 

 

 

 

 

 

 

 

IEC 61000-4-16

Mains Frequency Voltage

Signal ports

30V Continuous, 300V for 1s

4

 

 

 

D.C. Power ports

30V Continuous, 300V for 1s

4

 

 

 

 

 

 

 

IEC 61000-4-17

Ripple on D.C.

D.C. Power ports

10%

3

Power Supply

 

 

 

 

 

 

 

 

 

 

 

Signal ports

2kVAC (Fail-Safe Relay output)

N/A

 

 

 

 

 

IEC 60255-5

Dielectric Strength

D.C. Power ports

1.5kVDC

N/A

 

 

 

 

 

 

 

A.C. Power ports

2kVAC

N/A

 

 

 

 

 

 

 

Signal ports

5kV (Fail-Safe Relay output)

N/A

 

 

 

 

 

IEC 60255-5

H.V. Impulse

D.C. Power ports

5kV

N/A

 

 

 

 

 

 

 

A.C. Power ports

5kV

N/A

aRuggedCom-specified severity levels

Table 5.1. IEC 61850-3 EMI Type Tests

RuggedCom® RuggedBackbone™

43

RX1501 Installation Guide Rev 104

Page 43
Image 43
RuggedCom RX1501 manual EMI And Environmental Type Tests, Test Description Test Levels Severity, Esd