4. Technical Specifications
4. Technical Specifications
4.1. Power Supply Specifications
Power | Input Range | Internal | Max. Power | Max Power | Connections | ||
Supply Type | Min | Max | Fuse Rating | Consumptiona | Output | ||
HI | 88 VDC | 300 VDC | 2A(T)b | 52W Max | 42W | Screw | |
|
| ||||||
85 VAC | 264 VAC | terminal block | |||||
|
|
|
| ||||
|
|
|
|
|
|
| |
HIP | 88 VDC | 300 VDC | 2A(T)b | 52W Max | 42W | Pluggable | |
|
| ||||||
85 VAC | 264 VAC | terminal block | |||||
|
|
|
| ||||
|
|
|
|
|
|
| |
24 | 10 VDC | 36 VDC | 2A(T)b | 52W Max | 42W | Screw | |
|
|
|
|
|
| terminal block | |
24P | 10 VDC | 36 VDC | 2A(T)b | 52W Max | 42W | Pluggable | |
|
|
|
|
|
| terminal block | |
48 | 36 VDC | 72 VDC | 2A(T)b | 52W Max | 42W | Screw | |
|
|
|
|
|
| terminal block | |
48P | 36 VDC | 72 VDC | 2A(T)b | 52W Max | 42W | Pluggable | |
|
|
|
|
|
| terminal block |
aPower consumption varies based on configuration.
b(T) denotes
Table 4.1. Power Supply Specifications
4.2. Critical Alarm Relay Specifications
Voltage | Current |
30VDC | 5A |
|
|
250VAC | 6.25A |
|
|
Table 4.2. Form C Contact Relay Specifications
4.3. Copper Ethernet Port Specifications
The RX1501 can be ordered with several different modules which contain 10/100Tx or 10/100/1000Tx Ethernet ports. All copper Ethernet ports have the following specifications:
Parameter | Specification | Notes |
Speed | 10/100 or 10/100/1000 Mbps | |
|
|
|
Duplex | FDX / HDX | |
|
|
|
> Category 5 | Shielded/Unshielded | |
|
|
|
Wiring Standard | TIA/EIA T568A/B | |
|
|
|
Max Distance | 100 m |
|
|
|
|
Connector | RJ45 |
|
|
|
|
Isolation | 1.5kV | RMS |
|
|
|
Table 4.3. Copper Ethernet Port Specifications
RuggedCom® RuggedBackbone™ | 40 | RX1501 Installation Guide Rev 104 |