Ryobi RYI2000T Maintenance, Using the Battery Charging Cable, Moving the Generator

Models: RYI2000T

1 64
Download 64 pages 14.36 Kb
Page 18
Image 18

OPERATION

USING THE BATTERY CHARGING CABLE

See Figure 10.

WARNING:

The 12 V DC receptacle is designed to charge vented wet lead acid batteries, not to jump start vehicles. Do not overcharge battery or leave battery unattended.

CAUTION:

The 12 V DC receptacle provides continuous charge. Do not overcharge battery or leave battery unattended. Doing so may cause damage to the battery.

CAUTION:

Do not use the generator to jump start vehicles. Doing so could result in damage to the vehicle or it’s electrical components.

nUsing the battery clamps, connect the battery charging cable assembly to the battery terminal. Connect the red wire to the positive (+) terminal first, then connect the black wire to the negative (–) terminal. Make sure all connections are secure.

NOTE:  Be careful not to short across the terminals when installing. Shorting the terminals together can cause sparks, damage to the battery or generator, or even burns or explosions.

nConnect the battery charging cable assembly to the 12 V DC receptacle.

nStart the generator.

NOTE:  The AC receptacles can be used while the DC receptacle is in use.

nThe battery will become slightly warm to the touch while charging. This is normal and does not indicate a problem. NOTE:  Only use battery charging cable assembly to charge vented wet lead acid batteries.

nWhen batteries become fully charged, disconnect the battery charging cable assembly from the battery. Disconnect the negative (black) wire first, then the positive (red) wire, being careful not to short across the terminals. Always abide by the safety warnings provided with the battery.

NOTE:  Most batteries will be completely charged after 30 to 120 minutes. However, it is highly recommended that you refer to your battery manufacturer’s instructions for specific charge times.

nUnplug battery charging cable assembly and store for later use.

MOVING THE GENERATOR

See Figure 11.

nPut the on/off switch in the OFF ( O ) position.

nClose the vent on the fuel cap.

nAllow 30 minutes of “cool down” time before storing the machine.

nPull the retractable handle out.

nFacing the back of the generator, grasp the folding handle firmly with one hand.

nLift the generator toward you until it balances on the wheels.

nTurn around and pull the unit along behind you to the desired location.

nLower the generator until it sits securely on a flat surface.

MAINTENANCE

WARNING:

When servicing, use only identical replacement parts. Use of any other parts may create a hazard or cause product damage.

WARNING:

Always wear eye protection with side shields marked to comply with ANSI Z87.1. Failure to do so could result in objects being thrown into your eyes, resulting in possible serious injury.

GENERAL MAINTENANCE

Keep the generator in a clean and dry environment where it is not exposed to dust, dirt, moisture, or corrosive vapors. Do not allow the cooling air slots in the generator to become clogged with foreign material such as leaves, etc.

Do not use a garden hose to clean the generator. Water entering the fuel system or other internal parts of the unit can cause problems that will decrease the life of the generator.

To clean the unit:

nUse a soft bristle brush and/or vacuum cleaner to loosen and remove dirt and debris.

nClean air vents with low pressure air that does not exceed 25 psi.

nWipe the exterior surfaces of the generator with a damp cloth.

14 — English

Page 18
Image 18
Ryobi RYI2000T Using the Battery Charging Cable, Moving the Generator, General Maintenance, To clean the unit