INSTALLING THE OUTDOOR UNIT

InstallingandConnectingtheOutdoorUnitDrainHose(Exceptthecoolingonlymodels)

When using the air conditioner in the Heat mode, ice may accumulate. During de-icing, the condensed water must be drained off safely. Consequently, you must install a drain hose on the outdoor unit, following the instructions below.

1Insert the drain plug into the drain hole on the underside of the outdoor

unit.

2 Connect the drain hose to the drain plug.

Drain hole

3Ensure that the drained water runs off correctly and safely.

Fixing the Unit in Position

250 mm

506 mm

Rubber leg

The outdoor unit must be installed on a rigid and stable base to avoid any increase in the noise level and vibration, particularly if the outdoor unit is to be installed close to a neighbour.

If it is to be installed in a location exposed to strong winds or at a height, the unit must be fixed to an appropriate support (wall or ground).

1Position the outdoor unit so that the air flow is directed towards the outside, as indicated by the arrows on the top of the unit.

2Attach the outdoor unit to the appropriate support using anchor bolts.

3If the outdoor unit is exposed to strong winds, install shield plates around the outdoor unit, so that the fan can operate correctly.

Certainly fix up its rubber leg, in order to prevent its vibration and noise.

E-38