Choosing the installation location
Outdoor Unit
Where it is not exposed to strong wind
Well ventilated and dustless places
Where possible keep out of sunlight and rain
Where neighbors are not annoyed by operation sound or hot air
Solid wall or support that prevents vibration and is strong enough to hold the product weight
3m or more away from the TV or radio (to prevent the screen from being distorted or noise from being generated)
Install the unit horizontally
Place where drained water does not become any problem.
Place with no plants (especially climbing plants) and where small animal can not access.
Outdoor unit should not be place higher than 2.4 m or directly under eaves for accessibility for service and OH&S reasons.
•Avoid the following places to prevent malfunction of the unit
- Where there is machine oil | - Salty environment such as seaside areas |
| - Other special atmosphere areas |
Observe the clearances and maximum lengths as seenin the picture below when installing the air conditioner.
300 mm or more
125 mm |
| |
or more |
| |
Wrap the refrigerant pipes and the drain hose | You can select the direction of | |
with the absorbent pad and vinyl tape. Refer to | ||
draining | ||
page 44 for further details. | ||
(left or right). | ||
|
'L' m as maximum pipe length and 3 m as minimum pipe length (It will reduce noise and vibration)
600 mm | ' L ' meters maximum |
total pipe length | |
minimum |
|
300 mm |
|
minimum | 300 mm |
| |
| minimum |
600 mm |
|
minimum |
|
125mm or more
'H ' meters maximum total pipe height
Model | Pipe Length | Pipe Height | |
|
| ||
Minimum | Maximum | Maximum | |
|
|
|
|
**10/13** | 3 | 15 | 8 |
**18/24** | 3 | 30 | 15 |
Make at least one round: It will help reduce noise and vibration.
*
30
MAX_