There must be no space between the terminal and the screw when connected.
The terminal socket
is upside down. or there is a space between the screw and the ring terminal.
• For the terminal block wiring, use a wire with a ring terminal socket only.
CAUTION | ng work. |
*When you install the unit, makerefrigerant connections and then electrical connections. Connect the air conditioner to grounding system before performing the electrical connection. If unit is uninstalled, rst disconnect electrical cables, then refrigerant connections.
If the outdoor unit is more than 5 meters away from the indoor unit, you must extend the cable.
The maximum length of the cable is 15(**10/13**)/30(**18/24**) meters.
1. Extend the assembly cable if necessary.
• Do not connect two or morecables to extend the length.
2 . Open the front grille.
3 . Remove the screw securing the connector cover.
4 . Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals. (Refer to the picture below)
5 . Pass the other end of the cable through the 65 mm hole in the wall.
6 . Close the connector cover by tightening the screw carefully.
7 . Close the front grille.
8 . Remove the terminal board cover on the side of the outdoor unit.
9. Connect the cables to the terminals as seen in the picture.
Indoor unit | Indoor unit |
|
|
| |
| F1 | F2 |
| F1 | F2 |
Outdoor unit
Outdoor unit
F1 F2
• Each wire is labeled with the corresponding terminal number.
•Also circular terminal must be matched with screw size in terminal block.
• After connecting the cables, make sure terminal numbers on the indoor/outdoor unit matches.
•Please ensure that Power & Communication cables are separated, they must not be in the same cable.
10.Connect the grounding conductor to the grounding terminals.
11.Close the terminal board cover by tightening the screw carefully.
• Connect the wires according to color codes, referring to the wiring diagram.
34.
35
MAX_