Fixing the indoor unit in place

Perform the following work on the area where gas leak test was done priorly.

 

After checking for gas leaks in the system, insulate the pipe, hose and cables.

Insulation

Then place the indoor unit on the installation plate.

 

1. To minimise condensation problems, wrap foam insulation (as shown in

 

 

Pipes

2. Wind the pipe, assembly cable and drain hose with vinyl tape.

3.Place the bundle (the pipe, assembly cable and drain hose) in the lower part of the indoor unit carefully so it does not project from the rear of the indoor unit.

4.Hook the indoor unit to the installation plate and move the unit to the right and left until it is securely in place.

Make sure pipe does not move when you install the indoor unit on

an installation plate.

5.Wrap the rest of the pipe with vinyl tape.

6.Attach the pipe to the wall using clamps (optional).

Installation

 

plate

Connecting

Vinyl tape

pipes

Connecting wires

 

Drain hose

 

Fixing the outdoor unit in place

Install the outdoor unit in level on a stable base to help avoid the generation of noise and vibration, especially when installing the unit close to a neighbor.

appropriate support (wall or ground).

'X' mm

'Y' mm

1.

Place the outdoor unit as indicated on the top of the unit to let the discharged air out

Rubber leg

 

 

properly.

 

Model

X

Y

 

 

 

2.

Fix the outdoor unit in level to an appropriate support using anchor bolts.

 

**10/13**

538

290

3.

If the outdoor unit is exposed to strong winds, install shield plates around the outdoor

**18**

543

319

**24**

660

340

 

unit so that the fan can operate correctly.

 

 

 

 

 

 

 

• Secure the rubber leg to help prevent the generation of noise and vibration

 

 

 

 

 

Outdoor unit installed on the wall by rack

Designed to cut o residual vibration

 

from outdoor unit to rack.

 

 

 

 

 

 

 

 

(not supplied with product)

 

 

• Ensure the wall will be able to suspend the weight of rack and outdoor unit;

Install the rack close to the column as much as possible;

• Install proper grommet in order to help reduce noise and residual vibration transferred by outdoor unit towards wall.

Soft rubber designed to cut vibration from rack to wall. (not supplied with product)

44