63
3. Maintenance
Replacing the imaging unit
Click this link to open an animation about replacing the
imaging unit.
When a imaging unit has reached the end of life, the machine will
stop printing (see "Available supplies" on page 55).
1Open the front cover and pull the toner cartridge out.
2 Pull the imaging unit out.
3 Remove the new imaging unit from its bag.
Do not use sharp objects, such as a knife or scissors, to
open the toner cartridge package. They might scratch the
drum of the cartridge.
To prevent damage to the imaging unit, do not expose it
to light for more than a few minutes. Cover it with a piece
of paper, if necessary.