5-45-3
DIGITALVIDEO RECORDER
2
MANUAL ARCHIVE
The following illustration shows the initial settings of the MANUALARCHIVE menu.
MANUAL ARCHIVE
FROM RECORD EVENT LIST
FROM ALARM EVENT LIST
FROM MOTION EVENT LIST
TIME RANGE
DIRECT ARCHIVE
PICTURE SAMPLING RATE 1/1
MOVE=[///] SELECT=[ ] EXIT=[MENU]

(1) FROM RECORD EVENT LIST

If you have pressed the RECORD button on the main unit to record on the hard drive or if
you have recorded for a long time, the event list will be updated at a certain interval of time.
FROM RECORD EVENTLIST allows you to use this list to perform the backup, more
conveniently than using TIME RANGE. The following illustration shows the FROM
RECORD EVENTLIST screen in detail. The EVENT (RECORD), DATE and TIME
indicate when the event was recorded on the hard drive. To exit this screen and return to the
MANUALARCHIVE menu, press the MENU button.
RECORD EVENT ARCHIVE [1/7]
ID EVENT DATE TIME
01
RECORD
2003-07-13 09:23:55
[X]
02
RECORD
2003-07-12 13:43:21
[X]
03
RECORD
2003-07-12 11:13:42
[X]
04
RECORD
2003-07-11 09:23:55
[X]
05
RECORD
2003-07-11 05:11:42
[X]
06
RECORD
2003-07-10 23:51:12
[X]
07
RECORD
2003-07-10 13:37:48
[X]
MOVE=[///] START=[REC] EXIT=[MENU]
Use the LEFT(
), RIGHT(
), UP(
) and DOWN(
)
buttons to select the event you want to back up.
Ahighlighted cursor should appear over the selected item. Press the ENTER button ( ) to accept
the choice. The selected event will be indicated by "[O]". Repeat this procedure for each event you
want to back up, and then press the RECORD ( ) button to start the backup. The earliest event
occurrence will be backed up first.
Once the backup starts, the following information will be displayed.
Event Index
MACHINE : SCR-3000 MACHINE 1
RECORD START : 2003-06-14 09:45:28
CH No. : 1
REC MODE : 60.00 FPS
ARCHIVING START : 2003-06-14 09:55:35
ARCHIVING METHOD : MANUAL
ARCHIVE 2003-06-14 09:45:45
- MACHINE : "SCR-3000/SSC-Dual MACHINE 1" is the ID for the RS-485 connection.
- RECORD START: The date and time when the data you want to back up was recorded.
- CH No. : The input channel number of the data that you want to back up.
- REC MODE : The picture sampling rate of the recorded data that you want to back up
- ARCHIVING START: Backup start time.
- ARCHIVING METHOD : MANUALARCHIVE Method [MANUAL/TIMER/DIRECT]
Note
Note
In REC Mode - that is, if the picture rate of the data to be backed up is less than
15FPS(for NTSC) or 12.5FPS(for PAL) - no audio will be backed up.
REC