5-85-7
DIGITALVIDEO RECORDER
(4) TIME RANGE
From the MANUAL ARCHIVE menu, select "TIME RANGE" and the following screen
appears. In the TIME RANGE ARCHIVE screen, you can set the start and end times of a
particular section of the video and audio that you want to back up from the hard drive.
(5) DIRECTARCHIVE
DIRECTARCHIVE allows you to back up the desired scenes to a video tape regardless of
EVENTRECORD. First locate the desired scene. Next, press the VCR ( ) button to enter
VCR mode. Enter the MANUAL ARCHIVE menu, select DIRECT ARCHIVE, and then
press the ENTER ( ) button. The scene you have chosen will be backed up to the video
tape. If you perform DIRECTARCHIVE without locating the scene you want to back up, the
backup will start from the last position stopped at during playback.
(6) PICTURE SAMPLING RATE
PICTURE SAMPLING RATE allows you to reduce the picture sampling rate by a fraction-
al number when backing up the hard drive to a video tape. For example, if you set the rate
to 1/2 and back up the data that has been recorded at 30 fps, it will be backed up to the video
tape at 15 fps.
First select the event type. Next, set the start and end times of the section you want to back up.
For example, if you want to back up the RECORD and MOTION types of events, set these
two types of events to [O]. Next, enter the backup start and end times, and then press the
RECORD ( ) button. The RECORD and MOTION events within the specified time inter-
val will be backed up earliest to most recent. Even if ALARM events are found within the sec-
tion you have specified, they will be ignored because you did not select that event type.
Note
Note
- If MULTIPLEXER in the SYSTEM SETUP menu of the DVR MAIN MENU is set to
WITH, the MOTION event type will be disabled for SELECT EVENT in the TIME
RANGE menu. To perform the backup, set MULTIPLEXER in the SYSTEM SETUP
menu to WITHOUT.
Note
Note
- Even if you locate the desired scene and play it back in DVR mode for DIRECT
ARCHIVE, playback will stop as soon as you press the VCR button.
Note
Note
- If you back up the data after setting the picture sampling rate to a rate between
1/2 and 1/16, no audio will be backed up. Please note that this is not a malfunc-
tion.
TIME RANGE ARCHIVE
SELECT EVENT RECORD [X]
ALARM [X]
MOTION [X]
FROM 2003-07-10 13:37:48
TO 2003-07-13 22:43:54
MOVE=[///] SELECT=[REC] EXIT=[MENU]
Event Index
MACHINE : SCR-3000 MACHINE 1
RECORD START : 2003-06-14 09:45:28
CH No. : 1
REC MODE : 60.00 FPS
ARCHIVING START : 2003-06-14 09:55:35
ARCHIVING METHOD : MANUAL
ARCHIVE 2003-06-14 09:45:45
Event Index
MACHINE : SCR-3000 MACHINE 1
RECORD START : 2003-06-14 09:45:28
CH No. : 1
REC MODE : 60.00 FPS
ARCHIVING START : 2003-06-14 09:55:35
ARCHIVING METHOD : DIRECT
ARCHIVE 2003-06-14 09:45:45
REC
VCR