SHR-2040/2041/2042-ENG-1 2005.6.29 4:58 PM Page 3-8

5Connecting the RS-485 Device

Connect the RS-485 Device through the back port of SHR- SHR-2040/2041/2042.

You can install and control the PTZ camera supporting the RS-485 communication.

You can adopt either Half Duplex or Full Duplex method for the connection.

PTZ device

Half Duplex Type

Data (–)

Data (+)

Full Duplex Type

Rx(+)

Rx(–)

Tx(–)

Tx(+)

SHR-2040/2041/2042

Rear

Tx(–)

Tx(+)

Rx(–)

Rx(+)

Baud Rate supports 600/1200/2400/4800/9600/19200/38400.

Caution

Check if RS-485 device is compatible with SHR-2040/2041/2042 first. Then pay attention not to change the polarity(+, -) of RS-485 when connecting it.