English
9
Network Setup 5-32
Port setup for SmartViewer connection.
●The port value shall be the same as the Port(TCP/IP) value of the set to
register DVR(Setup ➝Site Setup) with SmartViewer.
●When you use an IP router, you shall forward the activated port by the current
setting value.
- In case of TCP/IP, set 4 ports(TCP/IP) in the IProuter.
- In case of UDP, set 4 ports(TCP/IP) and 160ports(UDP) in the IProuter.
When you set to TCP/IP from the Transfer Protocol Setttings page
●The ports set in Port(TCP/IP) shall be used to control SmartViewer connection
and transmit Stream.
When you set to UDP from the Transfer Protocol Setttings page
●The ports set in Port(TCP/IP) shall be used to control SmartViewer connection
and those set in Port(UDP) shall be used to transmit Stream.
●In case of Multicast
- The MultiCast IPand TTL Setup menu will be activated.
-
MultiCast IPindicates the group address for Multicast transmission(D-Class IP Address :
224.0.0.0 ~239.255.255.255).
- TTL(Time To Live) indicates how many routers Multicast shall get through.
- If you are unable to Multicast due to the network(LAN or ADSL) characteristics as both
the set and SmartViewer are installed, SmartViewer displays "Not Connected" in the
screen. In this case, reset to TCP/IPor UDP(Unicast).
●In case of abnormal screen replay from SmartViewer
- This may happen when the network bandwidth of the set is smaller than the packet
quantity of Transmission Stream. Then, reduce the IPsetup bandwidth(to 300Kbps or
600Kbps when installed to the ADSLnetwork).
- If this does not work, reset the protocol type to TCP/IP.
English
SHR-4081N/PUSER’S MANUAL
5-31
Callback Settings
●
Callback delivers a callback message to the IP where SmartViewer is already running when
an event corresponding to Alarm, Motion Detection, or Video Loss occurs from the set.
●On/Off : Off is the default and On is optional.
●IPAddress : IP setup is available only when On/Off is set to On. Sets up the IP
address of a PC where SmartViewer is already running.
●Port(UDP) : You may choose a value from 7900 to 7999, increasing by 1. Sets
up the port value of Callback Connection set by SmartViewer.
●Retry : You may choose a value from 1 to 20, increasing by 1.
Caution
Caution
- Though Callback is set to ON, there will be no Callback message unless Alarm,
Motion Detection, or Video Loss is set by Event Record.
- Unless you click the Callback button of SmartViewer, SmartViewer does not receive
any Callback message.
Note
Note
If you want to connect IPRouter with the main body of SHR-4081N/P, you shall
designate a port for SHR-4081N/Pin the IP Router setup menu.
The SHR-4081N/Pmain body uses 4 ports for TCP communication and further 160
UDPports when the procotol type is set to UDP. In addition, if you want to use the
DHCPfunction backed by IP Router to allocate Dynamic IP to the main body of
SHR-4081N/P, you shall designate a port for the IPwhich SHR-4081N/P has been allo-
cated by the IPRouter setup menu.
If you use IPRouter, you are recommended to rather determine IP and Port numbers to
be allocated to the main body of SHR-4081N/Pfrom the IP Router setup menu, set the
connection mode to Static IPfor the main body of SHR-4081N/P, and input the
determined IPand Port number in IP Router than use the DHCP function.
Please refer to the IPRouter User ’s Manual or call the manufacturer to set up IPRouter.