Functional Description
8.Others
▶ Main Menu/Camera Setting/Others
Functional Description
Sequence Setting
Main Menu
Sync : Enables selecting Internal Synchronization or the external Line Lock.
9.Power On Resume and MD Dwell Time
▶ Main Menu/Sequence Setting
① Camera Setting |
② Sequence Setting |
③ P/T Setting |
④ OSD Setting |
⑤ Alarm Setting |
⑥ Initialize |
Status |
➡
Camera Setting
① Focus & Zoom |
|
White Balance | ATW |
③ Exposure |
|
④ Back Light | OFF |
AGC | Medium |
SSNR | Medium |
⑦ Day & Night |
|
⑧ Others |
|
➡
Others
Sync | INTERNAL |
Stabilizer | OFF |
③ Image Adj |
|
Freeze | OFF |
Dome Cover | Inner |
-Internal : Synchronizes the camera’s output timing to the internal crystal.
-Line Lock : Synchronizes the camera’s output timing to the AC adapter power to synchronize multiple cameras.This option is useful when using a switch such as Matrix Switcher.
-Line Lock Phase : Enables setting the adapter’s synchronization phase between 0 and
360°.
Stabilizer : The Stabilizer compensates for any small movements of the camera caused by due to the wind and other reasonsor other causes.
Notes
• The Stabilizer uses the digital zoom and may cause low picture quality.
• The Stabilizer is disabled if the ambient light is too low.
• The Stabilizer is disabled if the field of view has very low or no contrast, e.g. The sky or a white wall.
Image Adj :
-Sharpness : Sharpens outlines of an image.
-Color :Adjusts the color density of an image.
Freeze : Stops or reanimates an image.
Dome Cover :
These settings are to optimize the camera’s focused object position according to the dome cover type.
-Inner : Default dome cover type including the indoor flush model. (Factory Release Mode)
-Outer : Dome cover type for outdoor housings except the indoor flush model.
-None :When using the camera without a dome cover.
Main Menu
①Camera Setting
② Sequence Setting
③ P/T Setting
④ OSD Setting
⑤ Alarm Setting
⑥ Initialize Status
➡
Sequence Setting
①Preset
② Swing SEQ
③ Group SEQ
④ Tour SEQ
⑤ PTZ Trace
⑥ Auto Run
Power On | Resume | ON |
MD Dwell | Time | ON |
Power On Resume :
This is useful when the power is disconnected and reconnected due to power failures or other power interruptions.
If the camera was performing a sequence action prior to a power disconnection, the camera automatically resumes the action when the power is reconnected.
MD Dwell Time :
When Motion Detection under the Preset Edit menu is selected, MD Dwell Time performs the Tour or Group function.
While the camera is performing a sequence action, if motion is detected from a selected preset location, the camera pauses the sequence action operation and starts monitoring the location instead for a duration that is set under the MD Dwell Time menu.
If the motion is no longer detectable or the duration expires, the camera aborts the monitoring operation and then resumes the sequence action.
SPEED DOME CAMERA 48 User’s Manual | SPEED DOME CAMERA 49 User’s Manual |