Samsung SSC-5000N manual Menu setup, Main Menu, Keyboard Setup, RS-485 Communication Setup

Models: SSC-5000N

1 31
Download 31 pages 11.28 Kb
Page 22
Image 22

MENU setup

MAIN MENU

1.Press the [MENU] button of the keyboard and a log-in window will appear as follows.

2.Using the number keys, enter the correct Operator No. and Password.

3.MAIN MENU will be displayed on the screen when you complete the log-in process.

4.Press the item you want to control on the main menu.

Press the <EXIT> icon in the main menu to return to the camera control mode.

M If the CHECK PASSWORD item is set “Off” in the keyboard setup, press the [MENU] button. MAIN MENU screen will directly appear without the log-in process.

M If you press the [MEMU] button while the OPERATOR’s LEVEL is the MANAGER’s or OPERATOR’s level, you cannot go into the menu.

Login

 

 

 

Operator No.

Password

 

 

Clear

 

 

Enter

MENU

Keyboard Setup

MAIN

Camera

000 Setup

 

 

DVR 001 Setup

KEYBOARD SETUP

On MAIN MENU, press <Keyboard Setup> to call the Keyboard Setup screen.

The KEYBOARD SETUP menu are constituted by 7 main items as follows.

Keyboard

RS-485 Communication Setup

Change Password

 

Setup

 

Check Password

On

 

 

Register New Operation

 

 

Camera Data Download

 

 

Camera Data Upload

 

 

System Information and Setup

RS-485 COMMUNICATION SETUP

On the Keyboard Setup menu, press <RS-485 Communication Setup>

and the RS-485 Communication Setup menu will appear on the screen.

M The default address of the keyboard is 0.

M The default Baud Rate of the keyboard is 9600BPS.

M The factory default setting of Duplex of keyboard is Half Duplex.

Keyboard

RS-485 Communication Setup

¨ Address Set

0

Setup

¨ Protocol (Port 1)

SAMSUNG

 

 

¨ Protocol (Port 2)

SAMSUNG

 

¨ Baud Rate

9600

 

¨ Duplex

Half Duplex

ADDRESS SET

The address of the system keyboard can be set.

1.Press <Address Set> and the keyboard address input window will appear as shown in the right figure.

2.Enter the address by using the number keys and press the [ENTER] button.

Press the <EXIT> icon on lower left if you want to clear the window without entering the address.

Input Keyboard Address (0~32)

Keyboard

 

Setup

 

Clear

Enter

M ADDRESS "0": For only one unit

ADDRESS "1~32": For multiple units connected together

M When using multiple units that are connected together, you must select a number between 1 and 32 before use. If the value is set to "0", this may cause communication to fail and malfunction.

M When using multiple units connected together and operating two separate keyboards at the same time, the first keyboard to start communication takes precedence.

22_ MENU setup

Page 22
Image 22
Samsung SSC-5000N manual Menu setup, Main Menu, Keyboard Setup, RS-485 Communication Setup