Drilling a Hole in the Wall

Drilling a Hole in the Wall

Drill a hole of 60mm(2 83 ") in diameter to the outside.

The drilling should be done at a distance of less than 150mm(5 78 ") from the floor facing the indoor unit.

ENGLISH

Less than 150mm (5 87" )

Drain Hose 60mm(2 3"8 )

Drain Hose

Extend the drain hose to the drain hose connected to

the drain pan, and fix it with the tape or a cable tie to prevent separation. Then make a covering of it so that water cannot flow outwardly.

 

Vinyl Chloride(Inner diameter ø 18mm

11

 

")

Piping Material

16

Outer diameter ø 23mm

7

")

 

8

 

 

 

 

 

 

Insulator

Foamed Polyethylene

 

 

 

 

 

 

 

CAUTION

1. As the draining is of natural drain type, make the drain hose direct downward.

2. If there is any foreign substance in the drain plate, it may clog the drain pipe. Therefore, be sure to remove the foreign substance inside after installation.

3. After completion of installation, be sure to pour water into the drain pan, and then check the draining condition.

(There is no problem in draining when the draining is completed within 20 seconds.)

Connecting the pipe

The piping of this unit can be connected to the right, left, or rear side. When you hit the area for piping connection slightly

with a hammer, a hole is made.

Holes for piping

 

connection (3 points)

E-31