Input Source Information Display

The Information Menu is used for checking the status of the image signal being projected and the operation of the projector.

Direct Operation

Press the INFO. button on the remote control to display the Information Menu.

Menu Operation

Press the Point ▲▼ buttons to select Information. The Information Menu is displayed.

See below for displayed information.

Input

The selected input source is displayed.

H-sync freq..

The horizontal frequency of the input signal is displayed in KHz or - - - - - when no signal.

V-sync freq..

The vertical frequency of the input signal is displayed in Hz or - - - - - when no signal. Numbers of Hz doubles when during Interlace.

Screen

The selected screen size is displayed.

Language

The selected language is displayed.

Lamp status

The selected lamp mode is displayed.

Lamp counter

The cumulative lamp operating time is displayed.

Power management

Off , Ready , Shut down or Timer is displayed.

Key lock

The selected Key lock icon is displayed.

PIN code lock

Off , On 1 or On 2 is displayed.

Remote control

The selected remote code is displayed.