Mechanical Disassemblies

bLamp Ballast Unit removal

1 Remove 1 screw A (M3x4) and remove SW902, and then remove 1 screw B (M3x6) and disconnect the Lamp Socket.

2 Remove 2 screws C (M3x6) to take the Lamp Ballast ass’y upward off.

3 Remove 2 screws D (T2x6) to take the isolation sheet off.

4 Remove 4 screws E (T3x6) to take the lamp ballast board off.

D

 

 

D

E

C

 

 

 

E

 

E

 

 

Isolation sheet

 

 

E

 

B

 

 

Lamp ballast board

 

A

SW902

 

 

nFilter Board removal

C

Lamp ballast socket

Fig.5

1 Remove 3 screws A (M3x6) and pull the Filter Board ass’y upward.

2 Remove 1 screw B (M4x8) to take the grounding lead from the cabinet bottom. 3 Remove 4 screws C (T3x8) to take the Filter Board off.

 

C

 

 

 

A

 

 

A

C

C

Filter board

 

C

A

B

Fig.6