Circuit Protections

This projector is equipped with the following circuit protections to operate in safety. If the abnormality occurs inside the projector, it will automatically turn off by operating one of the following protection circuits.

Fuse

The fuse is located inside of the projector. When either the LAMP indicator or the READY indicator is not illuminated, fuse may be opened. Check the fuse as following steps.

It should be used the specified fuse as follows;

Fuse Part No.: 423 022 2102

TYPE T4.0AH 250V FUSE

LITTLE FUSE INC. TYPE 215004

How to replace the fuse

1.Remove the cabinet top following to “Mechanical Disassemblies”.

2.Remove the fuse from fuse holder.

To install the fuse, take reversed step in the above.

Thermal switch

There is the thermal switch (SW902) inside of the projector to prevent the internal temperature from rising abnormally. When the internal temperature reaches near 100˚C, turn off the AC main power supply automatically.

The thermal switch is not reset to normal automatically even if the internal temperature becomes normal. Reset the thermal switch following procedure.

Check the resistance between terminals of thermal switch by using the tester. If it has high impedance, thermal switch may be in operative.

How to reset the thermal switch

1.Remove the cabinet top following to “Mechanical Disassemblies”.

2.Press the reset button on the thermal switch.

CAUTION:

Before press the reset button, disconnect the AC cord from the projector.

Line Filter Board

Fuse

Reset Button

Thermal switch (SW902)

Interlock switch

The interlock switch (SW904) cuts off the AC mains power supply when the lamp cover is removed. After opening the lamp cover for replacing the lamp ass’y, place the lamp cover correctly otherwise the projector can not turn on.

-6-

Page 6
Image 6
Sanyo PLC-XU45 service manual Circuit Protections, Type T4.0AH 250V Fuse Little Fuse INC. Type