Chapter 5 Network Viewer & Capture

5 Auto Display setting and control page [3]

Display period

Auto Control ....Displays period (3 to 240 sec.),

Repeating times (1 to 999 times)

*0 times represents endless dis- play

The display status is indicated on the text area.

Start

..............Starts automatic-image displaying

End

..............Quits automatic-image displaying

Stop

..............Stops automatic-image displaying

<<................Displays the previous image

>>................Displays the next image

Error

Displays the details when the file error is occurred

Click here to display the details when the file error is occurred.

*When the file error is occurred during the automatic display, you may have the alert e-mail message. For further information, please see item “4 Condition selection for sending alert message” (p.35).

*Error type

‘File Error’ ............It is displayed when the network unit cannot acquire the correct file images from the

ftp server, or when the master projector is turned off during the multi-control. Click Error button to check the details.

‘Connection Error’ ..It may be displayed when the slave projector is using the Network Viewer or capture function during the multi-control. For further error details, please see chapter “Multi Control/Check & Change” (p.82).

Caution

*The display period is greatly affected by the network environment or the operation of multi control, so it may not display the image as the specified display period.

*The switching is not the same timing between the images on the screen and on the web browser.