OUTPUT TERMINALS

SW OUT Terminal

When recording, a pulse signal is output at the SW OUT terminal.

This terminal is usually connected to the switch input (SW IN) of devices like a camera switcher unit, or a quad compressor.

FIELD: 16.7 msec.

FRAME: 5 msec.

5V (H)

(Output impedance: 5.7 kΩ) 0V (L)

SW OUT Terminal Output Setting

1Press the MENU button until the (SET UP 3) menu is displayed.

@@@@@@@<SET@UP@3>

öBUZZER

@@@ALARM@IN@@@@@@Y

@@@TAPE@END@@@@@@Y

@@@KEY@IN@@@@@@@@N

@@@WARNING@@@@@@@Y

öSW@OUT

@@@OUTPUT@@@@@@@@Y

@@@TIMING@@@@@@@@FIELD

@@@FIELD@@@@@@@@@01

2Press the ] button, until the “OUTPUT” setting is flashing.

3Press the l (or j) button, to set the desired output mode.

Y. . . . . . . . . . When recording, a pulse signal is output.

N. . . . . . . . . . When recording, a pulse signal is not output.

4Press the ] button, until the “TIMING” setting is flashing.

5Press the l (or j) button, to set “FIELD” or “FRAME”.

FIELD. . . . . . . 1 pulse is output after each set number of fields.

FRAME . . . . . 1 pulse is output after each set number of frames.

6Press the ] button, until the “FIELD” (or “FRAME”) setting is flashing.

NOTE:

If “TIMING” is set to FRAME (see step 5), “FRAME” will be indicated instead of “FIELD”.

7Press the l (or j) button, to set the desired pulse signal interval.

Available settings are:

FIELD . . . . . . . 01, 02, 03, 04, 05, 10, 30 or 60 field

FRAME . . . . . 01, 02, 03, 04, 05, 10, 30 or 60 frame

8Press the PAUSE/SEARCH button to save the setting.

SERIES OUT/NON REC OUT terminal setting

The output at the SERIES OUT/NON REC OUT terminal can be set.

1Press the MENU button until the (SET UP 2) menu is displayed.

@@@@@@@<SET@UP@2>

öDISPLAY

@@@DATE@@@@@@@@@@Y

@@@TIME@@@@@@@@@@Y

@@@ALARM@COUNT@@@Y

öTAPE@IN@MODE@@@@STOP

öTAPE@END@MODE@@@REW

öOUTPUT@@@@@@@@@@SERIES

öSERIES@REC@IN@@@N

öEJECT@MODE@@@@@@EJECT1

öTHREAD@CHECK@@@@Y

2Press the ] button, until the “OUTPUT” setting is flashing.

3Press the l (or j) button, to select the desired output mode.

SERIES . . . . . If during series recording, the counter reading reaches 7:57:00 or the tape reaches the end, a LOW signal (0 V) is output. The LOW (0 V) signal is output for about 70 seconds after the end of the tape is reached.

NON REC . . . If during recording the VCR enters a mode other than recording (i.e. recording pause, stop mode, etc.), a LOW signal (0

V)is output. If recording is resumed, then a HIGH signal (5

V)is output.

If in the (SET UP 3) menu, in the BUZZER section, WARNING is set to “Y”, a buzzer will be heard while the VCR is in non recording mode. The buzzer will stop if the STOP button is pressed (the output signal will remain LOW (0 V)).

4Press the PAUSE/SEARCH button to save the setting.

English