TROUBLESHOOTING GUIDE
If the unit does not operate normally when you follow the instructions indicated in the manual, please refer to the table below.
SYMPTOM | POSSIBLE CAUSE | CORRECTIVE ACTION | |
|
|
| |
No power | The power cord is not connected | Connect the power cord | |
|
|
| |
No image displayed on | The connections are not correct | Check that all connections are correct | |
the monitor TV |
|
| |
The power to the camera and/or monitor TV | Turn all connected devices power on | ||
| |||
| is not turned on |
| |
|
|
| |
The buttons do not | A cassette tape is not loaded | Load a cassette | |
respond |
|
| |
All functions are suspended due to | Wait for the “À” indicator to go off | ||
| |||
| condensation |
| |
|
|
| |
| Alarm recording | Wait for the alarm recording to end | |
|
|
| |
| The security lock is engaged | Cancel the security lock | |
|
|
| |
Recording is not | The loaded cassette has no | Load a cassette tape with | |
possible (the tape is | |||
ejected) |
| with adhesive tape | |
|
|
| |
Autorepeat recording is | “AL” is displayed on the digital display | Display (ALARM TIME) menu, then press | |
not possible |
| the MENU RESET button to turn off the | |
|
| “AL” indicator | |
|
|
| |
Alarm recording is not | “OFF” is displayed on the digital display | Press the EJECT, STOP, PLAY, FF or | |
possible |
| REW button to turn the indicator off | |
|
|
| |
Noise in the playback | The video heads need cleaning | Clean the video heads | |
picture |
|
| |
|
|
| |
The date and time are | The ON SCREEN switch is set to the “OFF” | Set the ON SCREEN switch to the “ON” | |
not recorded | position | position | |
|
|
| |
The cassette tape | Problem with the system | Unplug the power cord then plug it back in | |
cannot be ejected |
|
| |
|
|
| |
The cassette is ejected | The tape is not threaded correctly | Try inserting the cassette one more time or | |
a few seconds after it |
| using a new cassette. If it is ejected again, | |
has been inserted |
| please consult your dealer. | |
|
|
|
System Down
If the unit does not function at all, try the following.
1Unplug the power cord then plug it back in.
2Reset the memory. (Press the ALL RESET button. Under normal conditions, do not touch the ALL RESET button.)
3If the problem is not corrected after performing steps 1 and 2 a few times, consult your dealer.
English | 31 |