OUTPUT TERMINALS

TAPE END OUT Terminal

During recording, when the end of the tape is reached or when the tape counter reading indicates 7 hours 57 minutes or more, the output becomes 0V (Low).

To reset the output, press the STOP or EJECT button.

During autorepeat recording, when the end of the tape is reached, the output becomes 0V (Low) for about 2 seconds only.

Tape end or 7:57:00

Output reset

5V (H)

(Output impedance: 5.7 kΩ) 0V (L)

TAPE END OUT Terminal Output Setting

1Press the MENU button until the (SET UP 3) menu is displayed.

@@@@@@@<SET@UP@3>

*ALARM@MODE@@@@@@@Y1

*ALARM@SPEED@@@@@@8H

*ALARM@DURATION@@@20S

*VERTICAL@SYNC@@@@Y

*EXT@TIME@ADJ.@@@@01:00

*TAPE@IN@MODE@@@@@STOP

*TAPE@END@MODE@@@@REW *TAPE@END@OUT@@@@@-3M *CLOG@DETECT.@@@@@Y *SERIES@REC@IN@@@@N

2Press the ] button until the “TAPE END OUT” setting is flashing.

3Press the l (or j) button, to select the desired output mode.

–3M . . . . . . . . The output becomes 0 V (Low) when the tape counter reaches “7:57:00” and/or when the tape reaches the end.

END . . . . . . . . The output becomes 0 V (Low) when the tape reaches the end.

4Press the PAUSE/SEARCH button to save the setting.

SW OUT Terminal

When recording, a pulse signal is output at the SW OUT terminal.

This terminal is usually connected to the switch input (SW IN) of devices like a camera switcher unit, or a quad compressor.

FIELD: 16.7 msec.

FRAME: 5 msec.

5V (H)

(Output impedance: 5.7 kΩ) 0V (L)

SW OUT Terminal Output Setting

1Press the MENU button until the (SET UP 4) menu is displayed.

@@@@@@@<SET@UP@4>

*SW@OUT

@@TIMING@@@@@@@@@@FIELD

@@FIELD@@@@@@@@@@@01

@@8H@@@@@@@@@@@@@@Y

*THREAD@CHECK@@@@@Y

*VIDEO@LOSS@@@@@@@N

*REC@SPEED@@@@@@@@N

*EJECT@SET

@@EJECT@MODE@@@@@@EJECT1

@@OPERATION@@@@@@@SLAVE

2Press the l (or j) button to set “FIELD” or “FRAME”, then press the ] button.

FIELD . . . . . . . 1 pulse is output after each set number of fields.

FRAME. . . . . . 1 pulse is output after each set number of frames.

3Press the l (or j) button to set the desired pulse signal interval, then press the ] button.

If “TIMING” is set to FRAME (see step 4), “FRAME” will be indicated instead of “FIELD”.

Available settings are:

FIELD . . . . . . . 01, 02, 03, 04, 05, 10, 30 or 60 field

FRAME. . . . . . 01, 02, 03, 04, 05, 10, 30 or 60 frame

4Press the l (or j) button to set the desired “8H (or 6H)” mode.

If the“TAPE” in the (SET UP 5) menu is set to “T-120”, “6H” will be indicated instead of “8H”.

Y. . . . . . . . . . . When recording in 8-hour (or 6-hour) mode, a pulse signal is output.

N. . . . . . . . . . . When recording in 8-hour (or 6-hour) mode, a pulse signal is not output.

5Press the PAUSE/SEARCH button to save the settings.

40