OPTION SETTING

3, 4 ALARM SETTING

ALARM IN

ALM

POLARITY

NO

MOTION

OFF

DURATION

5S

ALARM OUT

OFF

POLARITY

NO

ALARM TIME

5S

LINE OUT

OFF

4POLARITY setting

Use the cursor button (j or l) to move the cursor to POLARITY, then use the cursor button (d or c) to select “NO” or “NC”.

Available settings:

NO: Normal open (Normally open so closed condition is detected as input.)

NC: Normal closed (Normally closed so open condition is detected as input.)

5Motion sensor input setting (MOTION)

Use the cursor button (j or l) to move the cursor to MOTION, then use the cursor button (d or c) to select the input.

Matches information from the camera’s motion sensor and the external alarm and outputs it.

Available settings:

OFF: Does not output a motion sensor alarm.

AND: Outputs an alarm when an external alarm input and motion sensor alarm are detected at the same time.

12

DURATION

ALARM OUT

ALARM TIME

1External alarm input2 Motion sensor detection

OR: Outputs an alarm if either an external alarm or a motion sensor alarm is detected.

6Alarm duration setting (DURATION)

Use the cursor button (j or l) to move the cursor to DURATION, then use the cursor button (d or c) to select the alarm duration.

Set the duration for the following alarm input reception.

Available settings: 5S (default setting), 10S, 15S, 20S, 30S, 1M, 2M, 3M, 4M, 5M

To close the menu screen or return to the previous screen, select BACK or END for MENU and press the SET button.