OPTION SETTING

CAlarm output setting (ALARM OUT)

1

ALARM SETTING

 

2

ALARM SETTING

 

 

ALARM IN

ALM

 

ALARM IN

ALM

 

POLARITY

NO

 

POLARITY

NO

 

MOTION

OFF

 

MOTION

OFF

 

DURATION

5S

 

DURATION

5S

 

ALARM OUT

OFF

 

ALARM OUT

OFF

 

POLARITY

NO

 

POLARITY

NO

 

ALARM TIME

5S

 

ALARM TIME

5S

 

LINE OUT

OFF

 

LINE OUT

OFF

1ALARM OUT setting

Use the cursor button (j or l) to move the cursor to ALARM OUT, then use the cursor button (d or c) to select “ON” or “ OFF”.

Available settings:

ON: Output an alarm (for activation of buzzer or lamp)

OFF: Does not output an alarm

2POLARITY setting

Use the cursor button (j or l) to move the cursor to POLARITY, then use the cursor button (d or c) to select “NO” or “NC”.

Available settings:

NO: Normal open (Normally open so closed condition is detected as input.)

NC: Normal closed (Normally closed so open condition is detected as input.)

3ALARM SETTING

ALARM IN

ALM

POLARITY

NO

MOTION

OFF

DURATION

5S

ALARM OUT

OFF

POLARITY

NO

ALARM TIME

5S

LINE OUT

OFF

3ALARM TIME setting

Use the cursor button (j or l) to move the cursor to ALARM TIME, then use the cursor button (d or c) to select the amount of time for external alarm output.

Available settings: 5S, 10S, 15S, 20S, 30S, 1M, 2M, 3M, 4M, 5M

To close the menu screen or return to the previous screen, select BACK or END for MENU and press the SET button.