Schlage SRP-275 user manual Printer does not start printing

Models: SRP-275

1 39
Download 39 pages 16.61 Kb
Page 38
Image 38

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SRP-275

• Errors that are impossible to recover

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error

 

Description

 

ERROR LED blinking pattern

Recovery

 

After

R/W

checking,

the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

printer

does not

work

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R/W error in memory

correctly.

 

 

 

 

 

 

 

200ms

Recovers

automatically

Writing to,

reading

out,

or

 

 

 

 

when the

rear cover is

or gate array

 

 

 

 

 

 

 

 

erasing the NV memory for

 

 

 

 

 

 

 

 

closed.

 

 

 

 

 

 

 

 

 

 

 

 

image

scanning

results

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

does not work correctly.

 

 

 

 

 

 

 

 

 

 

 

High voltage error

The power supply voltage

 

 

 

 

 

 

 

 

Impossible to recover.

is extremely high.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low voltage error

The power supply voltage

 

 

 

 

 

 

 

 

Impossible to recover.

is extremely low.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The CPU

executes

an

 

 

 

 

 

 

 

 

 

 

CPU execution error

incorrect address

or

I/F

 

 

 

 

 

 

 

 

Impossible to recover.

 

board is not connected.

 

 

 

 

 

 

 

 

 

 

 

Print head temperature

There is an abnormality is

 

 

 

 

 

 

 

 

Impossible to recover.

detection circuit error.

the print head temperature.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES

If you see this light blinking, turn off the printer for a few seconds and then turn it back on. If the light is still blinking, call your supervisor or a service person.

11-2 The printer does not start printing

Are any of the operation panel lights on, If no operation panel lights are on, check the following:

-Make sure that the printer is turned on.

-Make sure that the power supply cable is correctly plugged into the printer and to the power outlet.

If any of the lights are on, please check the following:

-If the POWER LED is blinking, the printer is not ready yet.

Wait until the light quits blinking and the printer is ready to use.

-If the ERROR LED is on (but not blinking), the printer is off line. Check to see that the covers are closed and check the paper state. See Chapter 5 for instructions on installing or replacing the paper roll.

-If the ERROR LED is blinking, there is an error. In this case, turn off the printer for a few seconds and then turn it back on. If the light is still blinking, call your supervisor or service person.

-If the PAPER OUT LED is on, check the paper roll in the printer. See Chapter 5 for instruction on installing the paper roll.

Rev. 1.01

- 38 -

Page 38
Image 38
Schlage SRP-275 user manual Printer does not start printing, If any of the lights are on, please check the following