Industrial Control Transformers

Multiple Secondary

Type T Units with Dual 24/120 Volt Secondary (Separate Windings)

Voltage and Connection Options

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H1

 

 

H2

 

 

H3

Voltage

Voltages

 

 

 

 

 

 

 

 

 

Connections

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Primary

 

Secondary

 

 

 

 

Primary

 

 

 

 

 

Secondary

 

 

 

X4

 

X3

X2

X1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D115

208/277

24/115

208:

 

Connect to H1 and H2

24:

 

 

Connect to X1 and X2

 

 

 

 

 

 

 

 

277:

 

Connect to H1 and H3

115:

 

 

Connect to X3 and X4

H1

 

 

 

 

 

H2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

550

23/110

 

 

 

 

 

 

 

 

 

23/24/25:

 

Connect to X1 and X2

 

 

 

 

 

 

 

 

D116

575

24/115

 

 

 

Connect to H1 and H2

 

 

 

 

 

 

 

 

 

 

 

 

110/115/120:

Connect to X3 and X4

X4

 

X3

X2

X1

 

 

600

25/120

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

380:

 

Connect to H1 and H2

24:

 

 

Connect to X1 and X2

H1

 

H2

H3

H4

D119

380/400/415

24/115

400:

 

Connect to H1 and H3

 

 

 

 

115:

 

 

Connect to X3 and X4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

415:

 

Connect to H1 and H4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X4

 

X3

X2

X1

Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

115

 

24

 

Simultaneous

VA

 

 

 

 

 

A

 

 

B

 

C

 

E

 

F

 

Slots

Only

 

Only

 

Catalog

 

Fig.

Acc.

 

 

 

 

 

 

 

Max

 

Max

 

Loading Max

 

 

Number1

 

Key

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VA

 

VA

 

 

UL VA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UL

CE

 

 

 

 

 

IN

 

mm

 

IN

 

mm

IN

mm

IN

 

mm

IN

 

mm

IN

mm

UL

 

UL

 

115V

24V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50

50

9070T50t

 

1

I

 

3.34

 

85

 

3.38

 

86

2.89

73

2.38

 

61

2.81

 

71

.20 x .48

5 x 12

50

 

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Any

75

75

9070T75t

 

1

I

 

3.59

 

91

 

3.75

 

95

3.20

81

2.88

 

73

3.13

 

80

.20 x .38

5 x 10

75

 

75

 

 

 

 

 

 

 

 

 

 

 

 

combination

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

100

9070T100t

 

1

I

 

3.59

 

91

 

3.75

 

95

3.20

81

2.88

 

73

3.13

 

80

.20 x .38

5 x 10

100

 

100

 

 

 

 

 

 

 

 

 

 

 

 

that does not

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

150

150

9070T150t

 

1

I

 

3.59

 

91

 

3.75

 

95

3.20

81

2.88

 

73

3.13

 

80

.20 x .38

5 x 10

150

 

150

 

 

exceed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Primary Max

200

200

9070T200t

 

2

I

 

4.74

 

120

 

4.50

 

114

3.84

98

2.56

 

65

3.75

 

95

.20 x .38

5 x 10

200

 

200

 

 

 

 

 

 

 

 

 

 

 

 

VA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

250

160

9070T250t

 

2

I

 

4.74

 

120

 

4.50

 

114

3.84

98

2.56

 

65

3.75

 

95

.20 x .38

5 x 10

250

 

250

 

 

 

 

 

 

 

 

 

 

 

 

For example,

300

200

9070T300t

 

2

I

 

5.11

 

130

 

4.50

 

114

3.84

98

3.00

 

76

3.75

 

95

.20 x .38

5 x 10

300

 

300

 

 

T350

 

 

 

 

 

 

 

 

 

200VA (120V)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

350

250

9070T350t

 

2

I

 

5.49

 

139

 

4.50

 

114

3.84

98

3.56

 

90

3.75

 

95

.20 x .38

5 x 10

350

 

350

 

 

 

 

 

 

 

 

 

 

 

150VA (24V)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

500

300

9070T500t

 

2

I

 

5.61

 

143

 

5.25

 

133

4.51

115

3.43

 

87

4.38

 

111

.28 x .56

7 x 14

500

 

500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1Complete the catalog number by replacing the t with the correct Voltage Code from the “Voltage and Connection Options” table above.

D A B D A B

C

C

FE

F

E

Figure 1

Figure 2

23

08/2005

 

 

 

© 1999–2005 Schneider Electric All Rights Reserved

Page 23
Image 23
Schneider Electric 9070 manual B D a B