INSTALLATION STEP 9

Electrical Requirements

To avoid installation difficulties, do not run the opener at this time.

To reduce the risk of electric shock, your garage door opener has a grounding type plug with a third grounding pin. This plug will only fit into a grounding type outlet. If the plug doesn'tfit into the outlet you have, contact a qualified electrician to install the proper outlet.

If permanent wiring is required by your local code, refer to the following procedure.

To make a permanent connection through the 7/8" hole in the top of the motor unit:

Remove the motor unit cover screws and set the cover aside,

Remove the attached 3-prong cord.

Connect the black (line) wire to the screw on the brass terminal; the white (neutral) wire to the screw on the silver terminal; and the ground wire to the green ground screw. The opener must be grounded.

Reinstall the cover.

TopreventpossibleSERIOUSINJURYor DEATHfrom electrocutionor fire:

Besure power is notconnectedto the opener,and disconnectpowerto circuit BEFOREremovingcoverto establishpermanentwiring connection.

Garagedoor installationand wiring MUSTbe in compliancewith all localelectricaland buildingcodes.

NEVERuse anextensioncord, 2-wire adapter,or changeplug in any wayto makeit fit outlet. Besure the openeris grounded.

PERMANENT WIRING

CONNECTION

Ground Tab

Green

Ground Screw

White /

2O