10. ACCEL & BRAKE(S)

In order to prevent an electric shock and short circuit, be sure to turn power off before performing work by touching the interior parts of the product.

Be careful so as not to damage wirings. Damaged wiring can cause an electric shock or short circuit accident.

Do not touch places other than those specified. Touching places not specified can cause an electric shock or short circuit accident.

If Accel and Brake operation is not satisfactory, adjustment of Volume installation position or Volume replacement is needed. Also, be sure to apply greasing to the gear mesh portion once every three months.

10 - 1 ADJUSTING AND REPLACING THE V.R.

Check Volume values in the Test Mode.

Since work is performed inside the energized cabinet, be very careful so as not to touch undesignated portions. Touch- ing places not specified can cause an electric shock or short circuit.

1Take out the 2 truss screws and remove the Front Cover

from the Accel. & Brake unit.

2Loosen the screw which secures the Potentiobase, and adjust the Volume Value by moving the Base.

3Secure the Potentiobase.

4Perform Volume setting in the Volume Setting Mode.

www.seuservice.com36

Page 41
Image 41
Sega 999-0886-01 owner manual Accel & Brakes, 10 1 Adjusting and Replacing the V.R