A. Specifications

Serial interface specifications

Input connector (25-pin serial)

 

 

 

 

 

13

1

 

 

 

 

 

25

14

RS-232C Pin assignments

 

 

 

 

 

PIN

SIGNAL

IN/OUT

PIN

SIGNAL

IN/OUT

 

1

CHASSIS GND

 

14

NC

 

 

2

TXD

OUT

15

NC

 

 

3

RXD

IN

16

NC

 

 

4

RTS

OUT

17

NC

 

 

5

CTS

IN

18

NC

 

 

6

DSR

IN

19

NC

 

 

7

SIGNAL GND

 

20

DTR

OUT

 

8

CD

IN

21

NC

 

 

9

NC

 

22

NC

 

 

10

NC

 

23

NC

 

 

11

SRTS

OUT

24

NC

 

 

12

NC

 

25

INC

 

 

13

NC

 

 

 

 

Notes:

1. NC stands for no connection.

 

2.CHASSIS GND and GND are connected in the printer.

Handshake protocol

One of the following four protocols can be selected:

-DTR protocol (Busy/Ready protocol)

-X ON/X OFF protocol I

-X ON/X OFF protocol II

-ETX/ACK protocol

Logic level ON=Space (0)=High:

12V (+3 through +15V) OFF=Mark (1)=LOW:

-12V (-3 through -15V)

Baud Rate

Input signal

75189 or equivalent

Input

330pF

Output signal

75188 or equivalent

Output

Inside printer

In the setup options, one of the following baud rates can be selected: 300, 600, 1200, 2400, 4800, 9600, 19200, and 38400 BPS.

Data frame

+3 +15V

-3-15V START D1 D2 D3 D4 D5 D6 D7

D8 STOP

101

Page 109
Image 109
Seiko BX-900 owner manual Serial interface specifications, 101