Seiko BX-900 owner manual Specified items on Bar Code, Bar Code command

Models: BX-900

1 146
Download 146 pages 27.38 Kb
Page 78
Image 78

9. Bar code and enlarged character

Specified items on Bar Code

 

Inter Character Gap

 

Height

(Example) CODABAR

 

 

START

Wide Space

STOP

Barcode

Character

Character

 

 

Narrow Space

 

 

Wide Bar

 

Check Character

 

 

Narrow Bar

HRI

Bar Code command

 

Function

Command

 

 

 

1.

Bar code type

DC4 DC4 T

 

 

 

2.

Element width

DC4 DC4 E

 

 

 

3.

Bar code height

DC4 DC4 H

 

 

 

4.

Setting HRI on and off

DC4 DC4 I

 

 

 

5.

HRI font

DC4 DC4 F

 

 

 

6.

Check character

DC4 DC4 C

 

 

 

7.

Starting the bar code data sequence

ESC SI

 

 

 

8.

Ending the bar code data seqence

ESC SO

 

 

 

9.

Bar code data sequence

DC4 DC4 B

 

 

 

10.

Printing density

DC4 DC4 D

 

 

 

11.

Guard bar expansion

DC4 DC4 G

 

 

 

12.

Start and stop characters

DC4 DC4 N

 

 

 

13.

Bar code rotational angle

DC4 DC4 R

 

 

 

14.

Disabling HRI of the start and stop characters

DC4 DC4 S

 

 

 

15.

Value input mode

DC4 DC4 V

 

 

 

16.

Initializing the bar code mode

DC4 DC4 @

 

 

 

(1)

Bar code type: DC4 DC4 T

Format: ASCII

DC4

DC4

T

n

Hex

14

14

54

n

Decimal

20

20

84

n

Function: Specifies the bar code type

n =0

Industrial 2 of 5

7

Code128

1

Interleaved 2 of 5

8

EAN-8

2

Matrix 2 of 5

9

EAN-13

3

Codabar

10

UPC-A

4

Code11

11

UPC-E

5

Code39

12

Postnet

6

Code93

255

Element Print

Parameter 255 (Element print) is used to print a bar code which is input element by element. It can print a bar code which is not supported by the printer and is represented by combining elements. Since data is input by elements, HRI printing is not performed and no check digit is added to the bar code. The start and stop characters is also not added.

70

Page 78
Image 78