AN.No.G1216B1N000-3D0E

1.9 Dimensions

Unit: mm

General dimensional tolerance:±0.5

Figure 1 Dimensions

I/O terminal functions

No.

Sym.

Functions

 

 

 

1

VDD

Power supply voltage: +5.0 V

2

VSS

GND: 0 V

3

VLC

LC drive voltage

4

DB0

Data bus (LSB)

5

DB1

Data bus

6

DB2

Data bus

7

DB3

Data bus

8

DB4

Data bus

9

DB5

Data bus

10

DB6

Data bus

 

No.

Sym.

Functions

 

 

 

11

DB7

Data bus (MSB)

12

CS1

Chip select (1)

 

 

 

 

13

CS2

Chip select (2)

 

 

 

 

14

RST

Reset

 

 

 

 

15

R/W

Read/Write

 

 

 

 

16

D/I

Data/Instruction

 

 

 

17

E

Enable

 

 

 

18

FGND

Frame ground1

19

LEDA

LED anode

 

 

 

20

LEDC

LED cathode

 

 

 

 

1FGND is connected to the metallic frame of the module. Use this frame when grounding.

- 6 -

Page 9
Image 9
Seiko Instruments G1216B1N000 user manual DB0, DB1, DB2, DB3, DB4, DB5, DB6, DB7, CS1, CS2, Rst