Receiver frequencies

4.1.2

DIVERSITY

A B

MENU

Y

N

SET

ESC

MANIPULATION

 

FUNCTION

 

DISPLAY (RX)

Chose option "RX-Freq." (chapter 4.1.1).

Depress

SET

to allow the receiver frequencies to be selected. The "M" on the display starts blinking.

24 MHz maximal

The EM 1046 RX receiver module can be configured as follows:

operation on max. 32 switchable frequencies or

variable adjustment of receiver frequencies (5 kHz grid) within 16 frequency ranges

The frequencies or frequency ranges selected must fall within the system's 24 MHz window. The configuration selected is stored in the EM 1046 RX receiver module by a personal computer via the service interface or by the remote computer. The configuration can be changed as often as desired.

Refer changes to the system configuration to your authorized Sennheiser distributor.

Example 1:

Variable adjustment within one frequency range (in the present case the total bandwidth of the system.

24 MHz maximal

24 MHz maximal

Example 2:

Variable adjustment within three frequency ranges. The frequencies between two adjacent frequency ranges cannot be used.

Example 3:

Seven selectable frequencies. The EM 1046 RX receiver modules come with this standard setting.

EM 203, Publ. 10/94 engl

20

Page 20
Image 20
Sennheiser FT-906B20, FT-905A, FT-902S35, FT-906A20, FT-902S15, FT-902S50 manual Manipulation Function Display RX