LC-52LE920UN/LC-60LE920UN
iv) Peel the protective sheet of the OCA.
Lift the ITOsection, then peel the protective sheet by about half bymeans ofthe pull tap.
* Peeling itcompletely reduces workability.
Check the order dueto workability.
v) Contact the FPCB and joint end of the transparent electrode film with the glass.
* Grasp the opposite end. Note that the ITO is positioned by adhering.
*Note: Do not bend the PWB (FPCB section)
and sheet (ITO section).
vi) Adhere the transparent electrode completely.
Peel the front protective sheet.
If bubbles are found, press those portions with glass
cleaning cloth, etc. to remove them as much as possible.
lPull tap for peeling the front protective sheet I
Use arubber roller since pressure exerted by itremoves bubbles easily. See photo below.
For the TOUCH SENSOR Unit positioning figure, see page 5-1, 5-2, 5-3, 5-4.
4-15