4) Other failure details (Flashes slowly 4 times and flashes fast)
Error type | Center | icon LED operation | |
Monitor | temperature | H: On |
|
failure |
|
|
|
Flashes | fast once | r_ | [q |
|
| ||
|
| L: Off |
|
Main failure | H: On |
| |
Flashes | fast 3 times |
|
|
|
| F_ |
|
L: Off
LC-52LE920UN/LC-60LE920UN
Note
Pins are monitor microcomputer pins unless other- wise specified.
If the panel temperature is 60°C or more for 15 seconds or more in a row, CAUTION appears on the OSD (flashes in red in the lower right screen).
If the panel temperature is 60°C or more for 25 seconds or more in a row, error standby is activated.
(MONITOR MAX TEMP on page 23 of the process A: Change of temperature failure AD value): Thermistor Main microcomputer detection error (CPU temperature error, etc.)
The details are displayed on page 1 of the process A of the main microcomputer.
4. Monitor ERR STBY table
Outline:
Location:
Communication/Power failure detected by the monitor microcomputer is stored on EEPROM, and the last 4 abnormal states can be confirmed in the process mode A.
Page 1 of the process mode A: MONITOR ERR CAUSE
"0" if there is no error. It is cleared to 0 on the last page of the process mode A.
Display |
|
|
|
|
|
|
|
| Error description |
|
|
|
| |||
02 | communication | error | 2 | Initial | communication | from the | main | CPU is not received. | ||||||||
03 | communication | error | 3 | Only | the initial communication | is received. | ||||||||||
04 | communication | error 4 | Until | panel information | request | reception | ||||||||||
05 | communication | error | 5 | Until | initialization | completion | reception | |||||||||
06 | communication | error | 6 | Until | version | notification | transmission |
| ||||||||
07 | communication | error | 7 | Until | information | notification | transmission | |||||||||
08 | communication | error | 8 | Until | information | response reception | ||||||||||
09 | communication | error | 9 | Until |
|
| ||||||||||
0A | Communication | error A |
| REQ |
|
|
|
|
|
|
| |||||
0B | Communication | error | B |
| Restart | the | beginning | of time acquisition | ||||||||
0C | Communication | error | C |
| Ending sequence |
|
|
| ||||||||
0D | Communication | error | D |
| Preset | |||||||||||
0E | Communication | error | E |
| download, |
|
|
| ||||||||
OF | Communication | error | F |
| Time acquisition |
|
|
| ||||||||
11 | Communication | error | H |
| Regular communication |
| ||||||||||
16 | error |
|
|
| Lamp | failure |
|
|
|
|
|
|
| |||
1A | Other | error 2 |
|
|
|
| Monitor temperature | failure |
|
|
| |||||
1E | Power |
| supply | error | 2 |
|
| D_POW (DET_13V) failure |
|
|
| |||||
1F | Power |
| supply | error | 3 |
|
| D_POW (DET_D3V3) | failure |
|
| |||||
21 | Power |
| supply | error | 5 |
|
| Panel | power | failure |
|
|
|
|
| |
23 | Other | error 3 |
|
|
|
| Error standby request from the main CPU |