LC-52LE920UN/LC-60LE920UN

LED flashing timing chart at the time of an error

100ms

400ms

 

1.6sec

1) Inverter/Lamp failure details (Flashes slowly once

and flashes fast)

Error

type

Center

icon

LED operation

Lamp failure

 

H: On

 

 

Flashes fast

once

 

 

 

L:Off

2)Power failure details Flashes slowly twice and flashes fast)

 

Error type

Center

icon

LED operation

SM

POW

 

H: On

 

 

 

Main

13V failure

 

 

 

 

Flashes

fast

twice

 

rq_q

I

 

 

 

 

 

 

 

 

L: Off

 

 

 

D POW

 

 

H: On

 

 

 

Digital 3.3V

failure

 

 

 

 

Flashes

fast 3 times

 

R

FLY[

 

 

 

 

 

L: Off

 

 

 

PANEL

POW

H: On

 

 

 

Panel 12V failure

 

 

 

 

Flashes

fast 5 times

_

R_

RTL

F1

L:Off

3)Communication failure details (Flashes slowly 3 times and flashes fast)

Error type

Center icon LED operation

Initial communica-

H: On

tion reception

failure

 

Flashes fast once

 

 

 

L: Off

Start-up confirma-

H: On

tion reception

failure

FLR

Flashes fast

twice

 

L: Off

Note

Pins are monitor microcomputer pins unless other- wise specified.

ERR_PNL(40pin): Hi failure. Confirmed after 8 consecu- tive detections at 64msec intervals (detected only when the backlight is on).

Note that after five detection counts, the lamp cannot be activated except in the monitor process.

Accumulated counts are cleared to 0 by the setting in the process A.

Note

Pins are monitor microcomputer pins unless other- wise specified.

DET_13V(38pin) failure (L). Main 13V is not applied.

If error is detected during start-up or operation, the power is turned on again by polling.

DET_D3V3(36pin) failure (L). Digital 3.3V is not applied.

If error is detected during start-up or operation, the power is turned on again by polling.

DET_PNL12V(35pin) failure (L). Panel power is not applied.

Detection is started after turning on the panel power and receiving command; the power is turned off by polling.

Note

Basically, debug print logs are analyzed or commu- nication logs are analyzed by a bus monitor.

Initial communication from the main CPU is not received. (Request for the monitor model No. is not received.)

--> Communication line failure or main CPU start-up fail- ure

Start-up reason confirmation from the main CPU cannot be received. (Start-up communication until start-up rea- son notification command is not received.)

--> Main CPU start-up failure or monitor microcomputer reception failure

Regular communica- tion failure

Flashes fast 3 times

Other communica- tion failure Flashes fast 5 times

H: On

F1 RTI

L:Off

H:On

_

H Iq RZI

L: Off

Regular communication that is performed at 1 second intervals in the normal operation is interrupted.

--> Main CPU operation failure or monitor microcom- puter reception failure

When a request (PM_REQ=H) is sent from the main microcomputer, the request command is not output from the main CPU, etc.

--> Main CPU operation failure or monitor microcom- puter reception failure

6-16

Page 62
Image 62
Sharp 60LE920UN, 52LE920UN Inverter/Lamp failure details Flashes slowly once, Error Type Center Icon LED operation