INSTALLATION AND REMOVAL OF EXHAUST HOSE

The exhaust hose must be installed or removed in accordance with the usage mode.

MODE

EXHAUST HOSE

 

 

COOL, FAN, VENTILATION, DEHUMIDIFICATION with no container

Install

 

 

DEHUMIDIFICATION with container(minimum capacity 31/ gallons)

Remove

2

 

Installation of the exhaust hose

1 Attach the window exhaust adapter to the exhaust hose.

Extend one end of the exhaust hose and insert it into the window exhaust adapter, and turn it (approx. three times) until it stops.

Make sure they are securely attached afterwards.

2

Attach the exhaust hose adapter to the

 

unit.

 

Insert the two projections on the exhaust

 

hose adapter into the two holes on the

 

unit, and firmly attach them to each

 

other.

3 Slide and open the exhaust cover on the window panel, and attach the window exhaust adapter.

Surface of window exhaust adapter marked "TOP" should be at the top when it is installed in a double-hung sash window.

Surface of window exhaust adapter marked "TOP" should be on the window frame side when it is installed in a sliding sash window.

Window exhaust adapter

Extend

Exhaust hose

Projection

Hole

"TOP"

The exhaust hose should be as short as possible for operational efficiency; however, it must not be twisted or bent.

Unacceptable Acceptable Acceptable

E-16