DEHUMIDIFICATION MODEIn this mode, the air conditioner dehumidifies the room.Dehumidification with container1 Remove the exhaust hose (See Page 17)2 Turn the drainage nozzle to the OPEN position.3 Pull the stopcock out from the drainage nozzle.

When the stopcock is removed, a small amount of water may be discharged from the drainage nozzle.

Always perform this procedure with the unit turned off. Drain water will spout out if attempted during operation.

4 Insert the hose clamp onto a standard commercially -available hose (5/8" inner diameter, 7/8" outer diameter) and attach the drain grommet to the hose.

5 Attach the hose to the drainage nozzle, and secure it with the hose clamp.

Insert the hose securely into a container with a minimum

capacity of 31/2 gallons. Be sure to monitor the water level in the container and empty as necessary. Do not operate in dehumidify mode for more than 8 hours at a time. Be sure to empty the water container whenever dehumidify mode is started. Failure to empty the water container can cause the container to overflow and cause damage to underlying materials.

Set the hose sloping downwards for easier drainage. Moreover, do not bend the hose at any point, nor allow the end to be submerged in water.

Drainage nozzle

Stopcock

"OPEN" position

Drain grommet

Hose clamp

Hose

ENGLISH

Dehumidification with no container

If draining of the water is not desirable, install the exhaust hose (See Page 16), turn the drainage nozzle to the CLOSE position, and check that the drainage nozzle is covered with the stopcock. In this operation, the water tank inside the unit may be full, the unit stops operating and then the TIMER, OPERATION and MEGA COOL lamps are blinking, depending on room condition. In this case, drain out the water within the unit (See Page 29).

1

Press the MODE button to select DEHU-

 

MIDIFICATION mode.

 

 

 

 

 

COOL DEHUM FAN

 

VENT

2 2

 

 

 

 

 

 

 

 

 

Press the power button to start opera-

 

tion.

 

 

 

 

• The red OPERATION lampon the unit will light.

 

• The temperature cannot be set.

 

• The fan speed is preset to AUTO and cannot be

 

changed.

 

 

 

1

TO TURN OFF

 

Press the POWER button again.

CAUTION

• The red OPERATION lamp on the unit will turn off.

When operating dehumidification with container, the unit generates heat during dehumidifica- tion mode and the room temperature will rise. Operate dehumidification with no container if you don't want the room temperature to rise. This will help to slightly drop the room temperature, but dehumidification performance will become less effective than when operating dehumidification with container.

E-21