Sharp MX-3500N manual Pull out the right side cover, Close the right side cover

Models: MX-3500N

1 69
Download 69 pages 63.35 Kb
Page 33
Image 33
Fusing unit pressure adjusting levers

Fusing unit pressure adjusting levers

In some cases damage to the envelopes, colour deviations, or smudging may occur even if envelopes within the specifications are used. This problem may be alleviated by shifting the fusing unit pressure adjusting levers from their "normal pressure position" to the "lower pressure position". Follow the procedure on the this page.

1

Pull out the right side cover.

While pushing up the open/close lever on the right side cover, gently open the cover.

B

A

Lower pressure position

2

Move the fusing unit pressure adjusting levers (two) to the lower pressure position as shown.

A: Front side of

Normal

B: Rear side of

position

fusing unit

fusing unit

 

Close the right side cover.

3

Pull out the right side cover.Caution

The fusing unit is hot. Take care not to burn yourself when operating the fusing unit pressure adjusting levers.

Be sure to return the levers to the "normal pressure position" before printing or copying on paper other than envelopes. Otherwise, fusing problems, paper misfeeds, or equipment failure may occur.