Controlling the Monitor with a PC

<Repeater control>

This system has a function to allow setting of multiple monitors connected in a daisy chain using a single command. This function is called repeater control.

You can use Repeater control function without assigning ID numbers.

[Example]

Set 1

Set 2

Set 3

Set 4

PC

If monitors are connected as shown above, you can execute a command like “Set all monitors’ input settings to DVI: DIGITAL”.

<Repeater control command>

Repeater control is achieved by setting the FOURTH CHARACTER of the parameter to “+”.

Example:

VOLM030+ ← Sets volume of all monitors to 30.

In repeater control, responses are returned by all the connected monitors.

If you want to determine that a value has been returned by a specifi c set, assign ID numbers to each monitor in advance.

When some monitors do not return their responses, the probable cause is that the monitors could not receive the command or command processing is not complete. Do not send a new command.

Example:

(When 4 monitors are connected, and assigned ID numbers: 1 through 4)

VOLM030+

 

WAIT

001

 

OK

 

 

 

 

 

 

 

 

 

 

 

 

OK

 

 

 

 

 

 

002

 

 

 

 

 

 

OK

 

 

 

 

 

 

003

 

 

 

 

 

 

OK

 

 

 

 

004

← If 4 monitors are connected in a chain, reliable operation can be ensured by sending

 

 

 

 

 

 

 

 

 

 

 

a new command only after a reply has been returned by 4th (last) monitor.

Repeater control can also be used for reading settings.

Example:

 

 

 

VOLM???+

 

 

 

WAIT

 

 

 

 

10

 

001

 

 

 

 

 

 

 

 

 

 

 

20

 

002

 

 

Volume settings for all monitors are returned.

 

 

 

30

 

003

 

 

 

 

 

 

 

 

 

30

 

004

 

 

 

 

 

 

 

 

 

 

 

 

 

TIPS

• If repeater control is used during ID designation (IDSL, IDLK), the ID designation is canceled.

ENGLISH

39 E