Controlling the Monitor with a PC

If execution of the command is taking some time

 

 

 

 

 

 

 

Return code

 

 

 

 

 

 

 

(0DH, 0AH)

W

A

I

T

 

 

 

 

 

 

 

 

 

 

When the following commands are used, “WAIT” is returned. In this case, a value will be returned if you wait a while. Do not send any command during this period.

No ID number is attached to WAIT response.

Commands which return WAIT:

-When repeater control is used

-When an IDSL or IDLK command is used

-When one of the following commands is used: RSET, INPS, ASNC, WIDE, EMAG, EPOS, PXSL, POWR, AGIN, MWIN, MWIP, MWPP.

When control via RS-232C is locked (to prevent use) using the operation lock function (see

ENGLISH

page 32)

L O C K E D

Return code (0DH, 0AH)

If the current parameter is read out using “?” for the parameter (for numerical values etc.)

Response when no ID number has been set

Example:

VOLM????

10

Response when an ID number has been set (In the example below: ID number = 1)

Example:

VOLM????

10

 

 

 

001

 

 

<Communication interval>

After OK or ERR is returned, you must send the following commands. To set a timeout for the command response, specify 10 seconds or longer.

Provide an interval of 100 ms or more between the command response and the transmission of the next command.

VOLM0020

OK

Interval of 100 ms or more

INPS0001

WAIT

OK