zWhen the engine is to start, there may be a case that the engine will not start unless the starter switch is restored to STOP once.
When the earth leakage breaker has activated, the earth leakage indication lamp turns ON and the breaker (lever) trips to the middle of ON and OFF positions. In the case, stop the engine promptly and find the leakage point to repair. After repairing leakage point(s), proceed with the following restoration steps.
①Push the reset button or stop the engine.
②Restore (push down) the breaker (lever) to OFF position.
By the above procedures, you can reset the breaker to ON position. <Caution>
zWhen the breaker trips to the middle but the lamp does not turn RED simultaneously, the cause is
5-4 The Slow-Down Feature
The
In the case of using the
Caution : Damage to the equipment or other properties
zTurn always the
<Caution>
zWhen the load of less than 0.5A is connected to use, the
zWhen welding operation or electric supply is used intermittently, turn the switch to OFF.
zWhen the output selector switch is positioned to ECO, the engine does not turn to high speed. (DGW311DM only)
6.Initialization and Pre-check
Caution : Fire・Burns・Injuries
zWhen checking engine, always stop the engine, and keep away from fire. Wait until the en- gine cools down, before performing any checks.
6-1 Checking Engine Oil
OIL GAUGE (YELLOW) | OIL FILLER |
|
When checking for engine oil, be sure to keep the equipment leveled, and insert the oil gauge all the way in.
Prior to starting the equipment, make sure to fill the engine oil to the HIGH level through the oil inlet.
SIDE DOOR | OIL PLUG (YELLOW) |
11