1015N-2MFM-1A

5.11015N-2M MODEM CARD INSTALLATION

WARNING: Set flowmeter and instrumentation power to OFF when inserting or removing the 1015N-2M Modem Card.

Before proceeding with the following installation procedures, identify the Module Loading option and installation drawing for your Modem Card (see Appendix A). The options are as follows:

a. Module Loading Option 1

1010N-5 with 1010N-2 in 1010N/DN Type System. Use Mounting Kit 1015N-2M-MK1. Refer to Installation Drawing 1015N-2M-MK-7 (sheet 1 of 3). Proceed to paragraph 5.1.1.

b. Module Loading Option 2

1010N-2 only in 1010N/DN Type System. Use Mounting Kit 1015N-2M-MK2. Refer to Installation Drawing 1015N-2M-MK-7 (sheet 2 of 3). Proceed to paragraph 5.1.2.

c. Module Loading Option 3

1010N-8M with 1010N-2M in 1010MN Type System. Use Mounting Kit 1015N-2M-MK3. Refer to Installation Drawing 1015N-2M-MK-7 (sheet 3 of 3). Proceed to paragraph 5.1.3.

5.1.1OPTION 1 INSTALLATION PROCEDURE (Mounting Kit 1015N-2M-MK1)1010N-5 Module with 1010N-2 Module in 1010N/DN Type System (Refer to Installation Drawing 1015N-2M-MK-7 sheet 1 of 3)

DISASSEMBLY (see Figure 2 and Figure 3)

1.Referring to Figure 1, open the 1010 NEMA flowmeter top cover by releasing the cover latch.

2.Place the power switch to the OFF position.

3.Loosen the captive thumbscrew securing the Access Cover and remove Access Cover.

Access Cover

Screw

1010N

Power Switich

Cover Latch

Figure 2. 1010N Flowmeter Access Cover Removal

3

Page 7
Image 7
Siemens 1015N-2MFM-1A manual 1015N-2M Modem Card Installation, Flowmeter Access Cover Removal