“AT” COMMANDS and ‘S” REGISTERS

Appendix A1015N-2MFM-1A

“AT” COMMANDS and ‘S” REGISTERS

EXCLUSIVE TO THE PE2400

Ampersand (AT&) Commands

 

Command

Factory Default

 

Parameters / Descrlptlon

 

 

 

 

 

&Dn

n = 0

Data Terminal Ready Option. &Dn controls the Data Terminal Ready (DTR) options.

 

 

 

Parameters: n = 0, 1, 2, 3

 

 

 

n = 0

Modem ignores DTR (factory default)

 

 

 

n = 1

Modem assumes command state when ON-to-OFF transition Is detected

 

 

 

 

on DTR.

 

 

 

n = 2

Modem hangs up, assumes command state and disables auto-answer

 

 

 

 

upon detecting ON-to-OFF transition on DTR.

 

 

 

n = 3

Modem assumes initialization state upon detecting an ON-to-OFF transition

 

 

 

 

on DTR.

 

 

 

Result codes: OK

 

&Jn

n = 0

Auxiliary Relay Control. &Jn determines how the auxiliary relay is controlled.

 

 

 

Parameters: n = 0.1

 

 

 

n = 0

The auxiliary telco relay is commanded to stay open. Suitable for RJ-11,

 

 

 

 

RJ-41 S, or RJ-45S type phone jack (factory default).

 

 

 

n =1

The auxiliary telco relay is controlled by off-hook/on-hook. If the modem is

 

 

 

 

off-hook, the relay is commanded to close (connectingAtoA1); if the modem

 

 

 

 

is on-hook. the relay is commanded to open (disconnecting A from A1).

 

 

 

 

Suitable for RJ-12 or RJ-13 type phone jacks.

 

 

 

 

 

Percent (AT%) Commands

Command

Factory Default

 

Parameters / Descriptlon

%Dn

n = 0

DTMF Attenuation. %Dn command sets the DTMF transmit level attenuation.

 

 

n = 0

0 dB attenuation

 

 

n =1

2 dB attenuation

 

 

n = 2

4 dB attenuation

 

 

n = 3

6 dB attenuation

 

 

n = 4

8 dB attenuation

 

 

n = 5

10 dB attenuation

 

 

n = 6

12 dB attenuation

 

 

n = 7

14 dB attenuation

%Ln

n = 0

Transmit Attenuation. %Ln command sets the transmit level attenuation.

 

 

n = 0

0 dB attenuation

 

 

n = 1

2 dB attenuation

 

 

n = 2

4 dB attenuation

 

 

n = 3

6 dB attenuation

 

 

n = 4

8 dB attenuation

 

 

n = 5

10 dB attenuation

 

 

n = 6

12 dB attenuation

 

 

n = 7

14 dB attenuation

 

 

 

 

A-6